Gdansk University of Technology, Faculty of Chemistry, Department of Chemical and Process Engineering, 80-233, G. Narutowicza St. 11/12, Gdansk, Poland.
Kettering University, Department of Chemistry & Biochemistry, 1700 University Avenue, Kettering Flint, MI 48504, USA.
J Chromatogr A. 2018 Jun 22;1555:10-19. doi: 10.1016/j.chroma.2018.04.054. Epub 2018 Apr 24.
The paper presents a new procedure for the determination of organic acids in a complex aqueous matrix using ultrasound-assisted dispersive liquid-liquid microextraction followed by injection port derivatization and GC-MS analysis. A deep eutectic solvent (choline chloride: 4-methylphenol in a 1:2 mol ratio) was used both as an extracting solvent and as a derivatizing agent to yield ion pairs which were next converted to methyl esters of organic acids in a hot GC injection port. The procedure was optimized in terms of selection of a deep eutectic solvent, disperser solvent, and the ratio of their volumes, pH, salting out effect, extraction time, injection port temperature and time of opening the split valve. The developed procedure is characterized by low LOD (1.7-8.3 μg/L) and LOQ (5.1-25 μg/L) values, good repeatability (RSD ranging from 4.0 to 6.7%), good recoveries for most of the studied analyte (81,5-106%) and a wide linear range. The procedure was used for the determination of carboxylic acids in real effluents from the production of petroleum bitumens. A total of ten analytes at concentrations ranging from 0.33 to 43.3 μg/mL were identified and determined in the effluents before and after chemical treatment. The study revealed that in effluents treated by hydrodynamic cavitation an increase in concentration of benzoic acid and related compounds was observed.
本文提出了一种新的程序,用于使用超声辅助分散液-液微萃取(DLLME)结合进样口衍生化和 GC-MS 分析,在复杂的水基质中测定有机酸。深共晶溶剂(氯化胆碱:4-甲基苯酚,摩尔比为 1:2)既用作萃取溶剂,也用作衍生化剂,生成离子对,然后在热 GC 进样口中将其转化为有机酸的甲酯。该程序在深共晶溶剂、分散溶剂的选择及其体积比、pH 值、盐析效应、萃取时间、进样口温度和分流阀开启时间方面进行了优化。所开发的程序具有低检出限(1.7-8.3μg/L)和定量限(5.1-25μg/L)、良好的重复性(RSD 范围为 4.0-6.7%)、对大多数研究分析物的良好回收率(81.5-106%)和宽线性范围。该程序用于测定石油沥青生产中实际废水中的羧酸。在未经和经化学处理的废水中鉴定并测定了浓度范围为 0.33-43.3μg/mL 的十种分析物。研究表明,在水力空化处理的废水中,苯甲酸和相关化合物的浓度增加。