Angle Orthod. 2018 Sep;88(5):611-616. doi: 10.2319/081717-556.1. Epub 2018 May 15.
To evaluate if a 0.5-mm vertical bend applied on an incisor bracket produces movements in other planes and if different wires influence these effects.
An acrylic model of a treated patient with brackets passively bonded was attached to an Orthodontic Force Tester, and a load cell was attached to the left lateral incisor. Thirty 0.019 × 0.025-inch archwires were divided into three groups according to their alloy: SS (stainless steel), B-Ti (beta-titanium), and MF (beta-titanium wire coated with nickel-titanium). Step-bends of 0.5 mm high were placed on the lateral incisor bracket using a universal plier, and the forces and moments in three dimensions were statistically analyzed by analysis of variance and Tukey post hoc test.
SS produced a larger force (3.4 N) than the B-Ti (1.41 N) and the MF (0.53 N; P < .001). Lingual forces were produced by the SS (0.82 N) and B-Ti (0.31 N) groups, while in the MF group, the force was insignificant. SS produced a mesial force of 0.24 N, while the B-Ti force was insignificant and MF produced 0.09 N. Groups produced different crown-distal tipping moments (SS = 31.48 N-mm, B-Ti = 11.7 N-mm, and MF = 4.55 N-mm) and different crown-buccal tipping moments. SS produced larger moments (3.63 N-mm) than B-Ti (1.02 N-mm) and MF (0.36 N-mm) wires. A mesial-out rotational moment was observed in all groups (SS = 7.17 N-mm, B-Ti = 3.46 N-mm, and MF = 0.86 N-mm).
A 0.5-mm intrusion bend produced lingual and mesial side effects. In addition to the distal and buccal crown-tipping moments, there was a mesial-out moment. Compared with SS, B-Ti and MF wires produced lower forces. These more flexible wires showed side effects with lesser intensity.
评估在托槽上施加 0.5 毫米的垂直弯曲会在其他平面上产生运动,以及不同的弓丝是否会影响这些效果。
将一个被动粘结托槽的治疗患者的丙烯酸模型固定在正畸力测试仪上,并在左侧侧切牙上安装一个测力传感器。将 30 根 0.019×0.025 英寸的弓丝根据其合金分为三组:SS(不锈钢)、B-Ti(β钛)和 MF(β钛丝涂覆镍钛)。使用万能弯丝钳在侧切牙托槽上放置 0.5 毫米高的台阶弯,通过方差分析和 Tukey 事后检验对三维力和力矩进行统计学分析。
SS 组产生的力(3.4N)大于 B-Ti 组(1.41N)和 MF 组(0.53N;P<0.001)。SS 组和 B-Ti 组产生舌向力,而 MF 组的力则不显著。SS 组产生近中向力 0.24N,而 B-Ti 组的力不显著,MF 组产生 0.09N。各组产生不同的冠向远中倾斜力矩(SS=31.48N-mm,B-Ti=11.7N-mm,MF=4.55N-mm)和不同的冠向颊侧倾斜力矩。SS 组产生的力矩(3.63N-mm)大于 B-Ti 组(1.02N-mm)和 MF 组(0.36N-mm)。所有组均产生近中向旋转力矩(SS=7.17N-mm,B-Ti=3.46N-mm,MF=0.86N-mm)。
0.5 毫米的压入弯曲产生了舌向和近中侧的副作用。除了远中冠和颊侧的倾斜力矩外,还有一个近中向的力矩。与 SS 相比,B-Ti 和 MF 产生的力较小。这些更柔软的弓丝产生的副作用强度较小。