Suppr超能文献

评价不同合金的上颌侧切牙托槽中单个倾斜曲产生的负载系统。

Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys.

出版信息

Angle Orthod. 2018 Sep;88(5):611-616. doi: 10.2319/081717-556.1. Epub 2018 May 15.

Abstract

OBJECTIVES

To evaluate if a 0.5-mm vertical bend applied on an incisor bracket produces movements in other planes and if different wires influence these effects.

MATERIALS AND METHODS

An acrylic model of a treated patient with brackets passively bonded was attached to an Orthodontic Force Tester, and a load cell was attached to the left lateral incisor. Thirty 0.019 × 0.025-inch archwires were divided into three groups according to their alloy: SS (stainless steel), B-Ti (beta-titanium), and MF (beta-titanium wire coated with nickel-titanium). Step-bends of 0.5 mm high were placed on the lateral incisor bracket using a universal plier, and the forces and moments in three dimensions were statistically analyzed by analysis of variance and Tukey post hoc test.

RESULTS

SS produced a larger force (3.4 N) than the B-Ti (1.41 N) and the MF (0.53 N; P < .001). Lingual forces were produced by the SS (0.82 N) and B-Ti (0.31 N) groups, while in the MF group, the force was insignificant. SS produced a mesial force of 0.24 N, while the B-Ti force was insignificant and MF produced 0.09 N. Groups produced different crown-distal tipping moments (SS = 31.48 N-mm, B-Ti = 11.7 N-mm, and MF = 4.55 N-mm) and different crown-buccal tipping moments. SS produced larger moments (3.63 N-mm) than B-Ti (1.02 N-mm) and MF (0.36 N-mm) wires. A mesial-out rotational moment was observed in all groups (SS = 7.17 N-mm, B-Ti = 3.46 N-mm, and MF = 0.86 N-mm).

CONCLUSIONS

A 0.5-mm intrusion bend produced lingual and mesial side effects. In addition to the distal and buccal crown-tipping moments, there was a mesial-out moment. Compared with SS, B-Ti and MF wires produced lower forces. These more flexible wires showed side effects with lesser intensity.

摘要

目的

评估在托槽上施加 0.5 毫米的垂直弯曲会在其他平面上产生运动,以及不同的弓丝是否会影响这些效果。

材料和方法

将一个被动粘结托槽的治疗患者的丙烯酸模型固定在正畸力测试仪上,并在左侧侧切牙上安装一个测力传感器。将 30 根 0.019×0.025 英寸的弓丝根据其合金分为三组:SS(不锈钢)、B-Ti(β钛)和 MF(β钛丝涂覆镍钛)。使用万能弯丝钳在侧切牙托槽上放置 0.5 毫米高的台阶弯,通过方差分析和 Tukey 事后检验对三维力和力矩进行统计学分析。

结果

SS 组产生的力(3.4N)大于 B-Ti 组(1.41N)和 MF 组(0.53N;P<0.001)。SS 组和 B-Ti 组产生舌向力,而 MF 组的力则不显著。SS 组产生近中向力 0.24N,而 B-Ti 组的力不显著,MF 组产生 0.09N。各组产生不同的冠向远中倾斜力矩(SS=31.48N-mm,B-Ti=11.7N-mm,MF=4.55N-mm)和不同的冠向颊侧倾斜力矩。SS 组产生的力矩(3.63N-mm)大于 B-Ti 组(1.02N-mm)和 MF 组(0.36N-mm)。所有组均产生近中向旋转力矩(SS=7.17N-mm,B-Ti=3.46N-mm,MF=0.86N-mm)。

结论

0.5 毫米的压入弯曲产生了舌向和近中侧的副作用。除了远中冠和颊侧的倾斜力矩外,还有一个近中向的力矩。与 SS 相比,B-Ti 和 MF 产生的力较小。这些更柔软的弓丝产生的副作用强度较小。

相似文献

2
Mechanical analysis of the improved superelastic Ni-Ti alloy wire using the orthodontic simulator with high-precision sensors.
J Mech Behav Biomed Mater. 2023 Jun;142:105861. doi: 10.1016/j.jmbbm.2023.105861. Epub 2023 Apr 24.
4
Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys.
Am J Orthod Dentofacial Orthop. 1990 Aug;98(2):117-26. doi: 10.1016/0889-5406(90)70005-W.
5
The effects of archwire forces on incisor intrusion.
Br J Orthod. 1995 May;22(2):155-60. doi: 10.1179/bjo.22.2.155.
6
Relative kinetic frictional forces between sintered stainless steel brackets and orthodontic wires.
Am J Orthod Dentofacial Orthop. 1995 Jan;107(1):20-7. doi: 10.1016/s0889-5406(95)70153-2.
8
Force system generated by elastic archwires with vertical V bends: a three-dimensional analysis.
Eur J Orthod. 2017 Apr 1;39(2):202-208. doi: 10.1093/ejo/cjw044.
9
Measurements of the torque moment in various archwire-bracket-ligation combinations.
Eur J Orthod. 2012 Jun;34(3):374-80. doi: 10.1093/ejo/cjr022. Epub 2011 May 13.
10
Evaluation of torque moment in esthetic brackets from bendable alloy wires.
Angle Orthod. 2021 Sep 1;91(5):656-663. doi: 10.2319/081820-729.1.

本文引用的文献

2
Orthodontic intrusion of maxillary incisors: a 3D finite element method study.
Dental Press J Orthod. 2016 Jan-Feb;21(1):75-82. doi: 10.1590/2177-6709.21.1.075-082.oar.
3
Nickel titanium T-loop wire dimensions for en masse retraction.
Angle Orthod. 2016 Sep;86(5):810-7. doi: 10.2319/070515-449.1. Epub 2016 Jan 13.
4
Archwire diameter effect on tooth alignment with different bracket-archwire combinations.
Am J Orthod Dentofacial Orthop. 2016 Jan;149(1):76-83. doi: 10.1016/j.ajodo.2015.06.026.
5
Differences in the force system delivered by different beta-titanium wires in elaborate designs.
Dental Press J Orthod. 2015 Nov-Dec;20(6):89-96. doi: 10.1590/2177-6709.20.6.089-096.oar.
6
Novel universal system for 3-dimensional orthodontic force-moment measurements and its clinical use.
Am J Orthod Dentofacial Orthop. 2015 Jul;148(1):174-83. doi: 10.1016/j.ajodo.2015.01.028.
9
Load system of segmental T-loops for canine retraction.
Am J Orthod Dentofacial Orthop. 2013 Oct;144(4):548-56. doi: 10.1016/j.ajodo.2013.05.007.
10
Effects of first- and second-order gable bends on the orthodontic load systems produced by T-loop archwires.
Angle Orthod. 2014 Mar;84(2):350-7. doi: 10.2319/031413-219.1. Epub 2013 Aug 29.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验