Jung Hyun Kyung, Park Young Mi, Baek Hye Jin, Choo Hye Jung, Kim Eun-Kyung, Kim Dong Wook, Lee Sun Joo, Lee Jin Hwa
Department of Radiology, Haeundae Paik Hospital.
Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan.
Ultrasound Q. 2019 Mar;35(1):93-98. doi: 10.1097/RUQ.0000000000000365.
This study aimed to compare the diagnostic performance of breast ultrasonography (US) with that of galactography in the detection of lesions in patients with pathologic nipple discharge.
We included 46 cases from 39 patients (all women; mean age, 44.0 years; range, 22-68 years) who had pathologic nipple discharge and underwent US and galactography between March 2004 and December 2012. Two radiologists retrospectively reviewed and compared the detectability of lesions on US and galactography images. A receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of US and galactography, and the area under the curve was compared between the 2 imaging modalities.
A total of 35 cases were pathologically diagnosed. Out of 11 cases that completed a follow-up, none developed malignancies during the follow-up period (mean: 63.5 months; range: 34.8-125.7 months). The sensitivity, specificity, and positive and negative predictive values of US with respect to detectability of lesions were 75%, 42.9%, 11.1%, and 94.7%, respectively, and those of galactography were 100%, 38.1%, 13.3%, and 100%, respectively.
Galactography is more sensitive than US in the detection of lesions in patients with pathologic nipple discharge.
本研究旨在比较乳腺超声(US)与乳腺导管造影在病理性乳头溢液患者病变检测中的诊断性能。
我们纳入了2004年3月至2012年12月期间39例(均为女性;平均年龄44.0岁;范围22 - 68岁)有病理乳头溢液并接受了超声和乳腺导管造影检查的46例患者。两名放射科医生回顾性地审查并比较了超声和乳腺导管造影图像上病变的可检测性。进行了受试者操作特征(ROC)曲线分析以评估超声和乳腺导管造影的诊断性能,并比较了两种成像方式之间的曲线下面积。
共35例经病理诊断。在完成随访的11例中,随访期间均未发生恶性肿瘤(平均:63.5个月;范围:34.8 - 125.7个月)。超声在病变可检测性方面的敏感性、特异性、阳性和阴性预测值分别为75%、42.9%、11.1%和94.7%,乳腺导管造影的分别为100%、38.1%、13.3%和100%。
在病理性乳头溢液患者病变检测中,乳腺导管造影比超声更敏感。