BACKGROUND

Metallosis is an uncommon phenomenon observed in late failures of cemented total knee arthroplasty (TKA), and it is rarely seen in the absence of metal-on-metal articulation.

METHODS

We report the case of a TKA patient with cemented titanium-alloy components and a polyethylene patella that was revised for early loosening with intra-operative severe metallosis.

RESULTS

We found that loosening and severe metallosis were associated with methacrylate particle abrasion on titanium alloy surfaces.

CONCLUSION

Serum titanium ion level measurement may be helpful in the workup of a painful TKA with titanium-alloy components in order to establish a diagnosis.

摘要

背景

金属沉着病是在骨水泥型全膝关节置换术(TKA)晚期失败中观察到的一种罕见现象,在非金属对金属关节的情况下很少见。

方法

我们报告了一例使用骨水泥型钛合金组件和聚乙烯髌骨的TKA患者,该患者因术中严重金属沉着病导致早期松动而进行翻修。

结果

我们发现松动和严重金属沉着病与钛合金表面的甲基丙烯酸酯颗粒磨损有关。

结论

测量血清钛离子水平可能有助于对使用钛合金组件的疼痛性TKA进行检查,以明确诊断。