Suppr超能文献

三维能量多普勒超声对单胎选择性胎儿生长受限双胎胎盘灌注的定量评估

Quantitative assessment of placental perfusion by three-dimensional power Doppler ultrasound for twins with selective intrauterine growth restriction in one twin.

作者信息

Sun Wei, Liu Jingyi, Zhang Ying, Cai Ailu, Yang Zeyu, Zhao Yili, Wang Yu, Cao Zhe, Wei Qiuju

机构信息

Department of Sonography, Shengjing Hospital of China Medical University, Shenyang, China.

Department of Obstetrics and Gynecology, Shengjing Hospital of China Medical University, Shenyang, China.

出版信息

Eur J Obstet Gynecol Reprod Biol. 2018 Jul;226:15-20. doi: 10.1016/j.ejogrb.2018.05.021. Epub 2018 May 17.

Abstract

OBJECTIVE

We quantitatively assessed placental perfusion using three-dimensional (3D) power Doppler ultrasound for twins with selective intrauterine growth restriction (sIUGR) in one twin.

STUDY DESIGN

A prospective cross-sectional study was performed for 104 normal monochorionic diamniotic twins and 30 twins with sIUGR. Twins with sIUGR were divided into two groups: in group I (19 twins), both fetuses had continuous forward end-diastolic blood flow in the umbilical artery; in group II (11 twins), the smaller fetus had a loss or a reverse end-diastolic blood flow in the umbilical artery, but the larger fetus had continuous forward end-diastolic blood flow. Volume data of the placenta was acquired in each twin at the plane where the umbilical cord entered the placenta by 3D power Doppler ultrasound, and imaging software was used to calculate the placental vascularization index (VI), flow index (FI), and vascularization flow index (VFI).

RESULTS

Among smaller fetuses, the sIUGR and control groups showed significant differences in VI and VFI, as well as significant differences between sIUGR group II and control group in FI. No such differences in placental perfusion were found among larger fetuses.

CONCLUSIONS

3D power Doppler ultrasound could sensitively display the varying degrees of changes in placental perfusion, which could be used for clinical monitoring of placental perfusion in sIUGR twins.

摘要

目的

我们使用三维(3D)能量多普勒超声对单绒毛膜双羊膜囊双胎中一胎发生选择性胎儿生长受限(sIUGR)的双胎胎盘灌注进行了定量评估。

研究设计

对104例正常单绒毛膜双羊膜囊双胎和30例sIUGR双胎进行了一项前瞻性横断面研究。sIUGR双胎分为两组:第一组(19例双胎),两胎儿脐动脉舒张末期血流均持续向前;第二组(11例双胎),较小胎儿脐动脉舒张末期血流消失或反向,但较大胎儿脐动脉舒张末期血流持续向前。通过3D能量多普勒超声在每个双胎脐带进入胎盘的平面获取胎盘容积数据,并使用成像软件计算胎盘血管化指数(VI)、血流指数(FI)和血管化血流指数(VFI)。

结果

在较小胎儿中,sIUGR组与对照组在VI和VFI方面存在显著差异,sIUGR第二组与对照组在FI方面也存在显著差异。在较大胎儿中未发现胎盘灌注存在此类差异。

结论

3D能量多普勒超声能够敏感地显示胎盘灌注的不同程度变化,可用于sIUGR双胎胎盘灌注的临床监测。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验