Peña Camila, Ortiz Manuela, Voisin Javier, Peralta Alexis, Balboa Viviana, Delgado Florencia
Sección de Hematología, Hospital del Salvador, Santiago, Chile.
Laboratorio Reumatología/Inmunología, Hospital del Salvador, Santiago, Chile.
Rev Med Chil. 2018 Jan;146(1):64-67. doi: 10.4067/s0034-98872018000100064.
International guidelines suggest a screening panel for monoclonal gammopathies that contains serum protein electrophoresis (SPE), free light chain (FLC) measurements and immunofixation. This combination provides the possibility of a timely accurate diagnosis.
To evaluate the sensibility of a simple screening panel (SPE + FLC).
We analyzed 191 consecutive serum samples of patients with a suspected monoclonal gammopathy (MG).
Seventy five patients were diagnosed with MG. The sensitivity and specificity of the combination of SPE + FLC for the diagnosis of monoclonal gammopathy were 95% (95% confidence intervals 89-99) and 99% (95% confidence intervals 96-100), respectively.
We were able to validate the international recommendations on the diagnostic accuracy of this simple combination of two tests in serum for monoclonal gammopathy.
国际指南建议采用一个包含血清蛋白电泳(SPE)、游离轻链(FLC)检测和免疫固定的单克隆丙种球蛋白病筛查组合。这种组合提供了及时准确诊断的可能性。
评估一个简单筛查组合(SPE + FLC)的敏感性。
我们分析了191例疑似单克隆丙种球蛋白病(MG)患者的连续血清样本。
75例患者被诊断为MG。SPE + FLC组合诊断单克隆丙种球蛋白病的敏感性和特异性分别为95%(95%置信区间89 - 99)和99%(95%置信区间96 - 100)。