Winzelberg G G, Hydovitz J D, O'Hara K R, Anderson K M, Turbiner E, Danowski T S, Lippe R D, Melada G A, Harrison A M
Radiology. 1985 Apr;155(1):231-5. doi: 10.1148/radiology.155.1.2983373.
Thallium-201/technetium-99m pertechnetate subtraction scintigraphy of the parathyroid glands was performed in a prospective study of 33 patients who had undergone bilateral neck exploration for elevated serum calcium and serum parathyroid hormone levels. In 31 cases, the Tl-201/Tc-99m subtraction technique yielded an overall sensitivity of 81%, specificity of 99%, and accuracy of 94% for identifying solitary parathyroid adenomas. Tl-201/Tc-99m subtraction scintigraphy correctly identified 73% of parathyroid adenomas weighing less than 499 mg, 79% of those weighing 500-1,499 mg, and 100% of adenomas weighing more than 1,500 mg. In a subgroup of 24 patients with solitary parathyroid adenomas who underwent both scintigraphy and high-resolution sonography, the sensitivity, specificity, and accuracy of both procedures were similar.
对33例因血清钙和血清甲状旁腺激素水平升高而接受双侧颈部探查的患者进行了甲状旁腺铊-201/锝-99m高锝酸盐减影闪烁扫描。在31例病例中,铊-201/锝-99m减影技术在识别孤立性甲状旁腺腺瘤方面的总体敏感性为81%,特异性为99%,准确性为94%。铊-201/锝-99m减影闪烁扫描正确识别了73%重量小于499毫克的甲状旁腺腺瘤、79%重量在500 - 1499毫克之间的腺瘤以及100%重量超过1500毫克的腺瘤。在24例接受了闪烁扫描和高分辨率超声检查的孤立性甲状旁腺腺瘤患者亚组中,两种检查方法的敏感性、特异性和准确性相似。