Suppr超能文献

使用 4 种不同体素大小的锥形束 CT 图像和 4 种不同软件对人工 ERR 腔进行线性和体积测量的准确性:一项离体研究。

Accuracy of linear and volumetric measurements of artificial ERR cavities by using CBCT images obtained at 4 different voxel sizes and measured by using 4 different software: an ex vivo research.

机构信息

1 Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University , Ankara , Turkey.

2 Department of Endodontics, Faculty of Dentistry, Başkent University , Ankara , Turkey.

出版信息

Dentomaxillofac Radiol. 2018 Dec;47(8):20170325. doi: 10.1259/dmfr.20170325. Epub 2018 Jun 27.

Abstract

OBJECTIVES

To compare the accuracy of linear and volumetric measurements of artificial external root resorption (ERR) cavities by cone beam CT (CBCT) images obtained at four voxel sizes and by using four different software ex vivo.

METHODS

ERR cavities were created on 40 extracted single rooted anterior teeth. Images were obtained by using Planmeca CBCT unit at endo mode (0.075 mm); high-resolution mode (0.1 mm); high-definition mode (0.15 mm) and normal resolution mode (0.2 mm) voxel sizes. Images were analyzed by two observers using four different software (Romexis, 3D Doctor, ITK-SNAP, and OsiriX). (1) Diameter; (2) height; (3) depth; and (4) volume of the ERR were measured. CBCT measurements were then compared with direct physical measurements. ANOVA was used with general linear model analysis. The significance level was set at p < 0.05.

RESULTS

One-way ANOVA general linear model analysis showed no significant difference between or within observers for diameter, height, depth and volume measurements (p > 0.05). We found significant differences for diameter and volume measurements among softwares in terms of mean differences as compared to mean standard direct measurements (p < 0.05). We found statistically significant differences among voxel sizes and software for height measurements (p < 0.05). In addition, we found significant differences for diameter and volume measurements (p < 0.05) suggesting more accurate measurements for the cervical region when compared to apical region.

CONCLUSIONS

Observers using CBCT images obtained at four voxel sizes performed similarly in the quantification of artificial ERR with clinically insignificant distinction between CBCT softwares used.

摘要

目的

比较使用四种不同软件在四种不同体素大小下的锥形束 CT(CBCT)图像对人工外根管吸收(ERR)腔的线性和体积测量的准确性。

方法

在 40 颗拔出的单根前牙上制作 ERR 腔。使用 Planmeca CBCT 单元在根管模式(0.075mm);高分辨率模式(0.1mm);高清模式(0.15mm)和标准分辨率模式(0.2mm)体素大小下获得图像。由两名观察者使用四种不同的软件(Romexis、3D Doctor、ITK-SNAP 和 OsiriX)对图像进行分析。(1)直径;(2)高度;(3)深度;(4)ERR 的体积。然后将 CBCT 测量值与直接物理测量值进行比较。采用一般线性模型分析进行方差分析。显著性水平设为 p < 0.05。

结果

单向方差分析一般线性模型分析显示,观察者之间或观察者内部在直径、高度、深度和体积测量方面没有显著差异(p > 0.05)。与直接标准测量的平均值相比,我们发现软件之间在直径和体积测量方面存在显著差异(p < 0.05)。我们发现体素大小和软件之间在高度测量方面存在统计学显著差异(p < 0.05)。此外,我们还发现直径和体积测量值存在显著差异(p < 0.05),提示与根尖区相比,颈区的测量更准确。

结论

使用四种体素大小的 CBCT 图像的观察者在人工 ERR 的定量方面表现相似,使用的 CBCT 软件之间没有临床意义上的区别。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验