Suppr超能文献

超声光谱固化监测传感器设计优化。

Sensor Design Optimization for Ultrasonic Spectroscopy Cure Monitoring.

机构信息

Institut for Adaptronics and Function Integration, Technische Universität Braunschweig, Langer Kamp 6, 38106 Braunschweig, Germany.

出版信息

Sensors (Basel). 2018 Jun 4;18(6):1819. doi: 10.3390/s18061819.

Abstract

In the field of cure monitoring, resonant ultrasonic cure monitoring is a unique technique to measure the progression of cure of composites in fully or partially closed tools. It allows for the use of electronic hardware that is less sophisticated than traditional pulse-based ultrasonic systems to obtain accurate results. While this technique is not new, it has been used very rarely. One reason for this is the lack of optimized sensors. Commercially available sensors are optimized for pulse-based ultrasonic testing. This paper establishes a possible optimized sensor design for resonant ultrasound cure monitoring using a multi-parameter FE model.

摘要

在固化监测领域,共振超声固化监测是一种独特的技术,可用于测量完全或部分封闭模具中复合材料的固化进度。它允许使用比传统基于脉冲的超声系统更简单的电子硬件来获得准确的结果。虽然这项技术并不新鲜,但它很少被使用。原因之一是缺乏优化的传感器。市售的传感器针对基于脉冲的超声测试进行了优化。本文使用多参数有限元模型为共振超声固化监测建立了一种可能的优化传感器设计。