Takao Toshitatsu, Masumura Ryo, Sakauchi Sumitaka, Ohara Yoshiko, Bilgic Elif, Umegaki Eiji, Kutsumi Hiromu, Azuma Takeshi
Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
NTT Media Intelligence Laboratories, NTT Corporation, Yokosuka, Japan.
Endosc Int Open. 2018 Jun;6(6):E676-E687. doi: 10.1055/a-0579-6494. Epub 2018 May 25.
We developed a new reporting system based on structured data entry, which selectively extracts only endoscopic findings from endoscopists' oral statements and automatically inputs them into appropriate columns in real time during endoscopic procedures.
We compared the time for endoscopic procedures and report preparation (ER time) by using an esophagogastroduodenoscopy simulator in three groups: one preparing reports using a mouse after endoscopic procedures (CE group); a second group preparing reports by using voice alone during endoscopic procedures (SR group); and the final group preparing reports by operating the system with a foot switch and inputting findings using voice during endoscopic procedures (SR + FS group). For the SR and SR + FS groups, we identified the recognition rates of the speech recognition system.
Mean ER times for cases with three findings each were 162, 130 and 119 seconds in the CE, SR and SR + FS groups, respectively. The mean ER times for cases with six findings each were 220, 144 and 128 seconds, respectively. The times in the SR and SR + FS groups were significantly shorter than that in the CE group ( < 0.017). The recognition rate of the SR group for cases with three findings each was 98.4 %, and 97.6 % in the same group for cases with six findings each. The rates in the SR + FS group were 95.2 % and 98.4 %, respectively.
Our reporting system was demonstrated to allow an endoscopist to efficiently complete the report in real time during endoscopic procedures.
我们开发了一种基于结构化数据录入的新报告系统,该系统可从内镜医师的口头陈述中选择性地仅提取内镜检查结果,并在内镜检查过程中实时自动将其输入到相应的栏目中。
我们使用食管胃十二指肠镜模拟器,在三组中比较了内镜检查和报告准备时间(ER时间):一组在内镜检查后使用鼠标准备报告(CE组);第二组在内镜检查过程中仅通过语音准备报告(SR组);最后一组在内镜检查过程中通过脚踏开关操作系统并使用语音输入检查结果来准备报告(SR+FS组)。对于SR组和SR+FS组,我们确定了语音识别系统的识别率。
每组有三个检查结果的病例,CE组、SR组和SR+FS组的平均ER时间分别为162秒、130秒和119秒。每组有六个检查结果的病例,平均ER时间分别为220秒、144秒和128秒。SR组和SR+FS组的时间明显短于CE组(<0.017)。SR组中每组有三个检查结果的病例识别率为98.4%,每组有六个检查结果的病例识别率为97.6%。SR+FS组的识别率分别为95.2%和98.4%。
我们的报告系统被证明可使内镜医师在内镜检查过程中高效地实时完成报告。