Suppr超能文献

三代陶瓷对陶瓷非骨水泥型全髋关节置换术:一项至少10年的随访研究。

3 generation ceramic-on-ceramic cementless total hip arthroplasty: a minimum 10-year follow-up study.

作者信息

Lau Yeong J, Sarmah Shashank, Witt Johan D

机构信息

University College Hospital, London - UK.

出版信息

Hip Int. 2018 Mar;28(2):133-138. doi: 10.1177/1120700018768617.

Abstract

INTRODUCTION

3 generation ceramic bearings were introduced in total hip arthroplasty (THA) with the potential to have better mechanical strength and wear properties than their predecessors. At present, there are few studies looking at the long-term results of this latest generation of ceramic bearings. The purpose of our study was to investigate the long-term clinical and radiographic results of 3 generation ceramic-on-ceramic THA and the incidence of ceramic specific complications such as squeaking and bearing surface fracture.

METHODS

The database of the senior author (J.D.W.) was reviewed. A total of 126 hip replacements performed in 108 patients (average age 39.6 years) with an average follow-up of 12.1 years (10-16 years) was identified. Clinical notes and plain radiographs were reviewed. To measure function, patients were contacted and an Oxford Hip Questionnaire was completed. Patients were also directly questioned about the presence of squeaking or any other sounds from the hip. Radiographs were evaluated for signs of wear, osteolysis, loosening and heterotopic ossification. The abduction angle of the acetabular component was measured.

RESULTS

The average Oxford Hip Score was 39.8 out of 48. Survivorship at 10 years was 94.6% (95% CI) with revision for any cause as the endpoint. There was 1 femoral head fracture, no osteolysis, no squeaking and no detectable wear.

CONCLUSIONS

The good clinical and radiographic results for this series of patients are similar to other recent long-term studies looking at 3 generation ceramic-on-ceramic THA. The results compare favourably with other bearing surfaces. The lack of osteolysis associated with this articulation is encouraging and may also make it a good choice for younger patients requiring total hip replacement.

摘要

引言

第三代陶瓷轴承被应用于全髋关节置换术(THA),其机械强度和磨损性能可能优于前代产品。目前,针对这一最新一代陶瓷轴承长期效果的研究较少。我们研究的目的是调查第三代陶瓷对陶瓷全髋关节置换术的长期临床和影像学结果,以及陶瓷特定并发症(如吱吱声和轴承表面骨折)的发生率。

方法

回顾资深作者(J.D.W.)的数据库。共确定了108例患者(平均年龄39.6岁)进行的126例髋关节置换手术,平均随访12.1年(10 - 16年)。回顾临床记录和X线平片。为评估功能,联系患者并完成牛津髋关节问卷。还直接询问患者髋关节是否有吱吱声或其他任何声音。对X线片进行磨损、骨溶解、松动和异位骨化迹象的评估。测量髋臼组件的外展角度。

结果

牛津髋关节平均评分为48分中的39.8分。以任何原因翻修为终点,10年生存率为94.6%(95%可信区间)。发生1例股骨头骨折,无骨溶解,无吱吱声,无可检测到的磨损。

结论

该系列患者良好的临床和影像学结果与近期其他关于第三代陶瓷对陶瓷全髋关节置换术的长期研究相似。结果与其他轴承表面相比有利。与这种关节置换相关的骨溶解的缺乏令人鼓舞,对于需要全髋关节置换的年轻患者来说,这也可能是一个不错的选择。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验