Dow Chemical Canada ULC, Highway 15, Fort Saskatchewan, Alberta, T8L 2P4, Canada; ARC Training Centre for Portable Analytical Separation Technologies (ASTech), University of Tasmania, Private Bag 75, Hobart 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart 7001, Australia.

Dow Chemical Canada ULC, Highway 15, Fort Saskatchewan, Alberta, T8L 2P4, Canada; Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart 7001, Australia.

出版信息

J Chromatogr A. 2018 Aug 17;1563:171-179. doi: 10.1016/j.chroma.2018.05.015. Epub 2018 May 8.

Abstract

An effective analytical strategy was developed and implemented to exploit the synergy derived from three different detector classes for gas chromatography, namely ultraviolet spectroscopy, flame ionization, and mass spectrometry for volatile compound analysis. This strategy was achieved by successfully hyphenating a user-selectable multi-wavelength diode array detector featuring a positive temperature coefficient thermistor as an isothermal heater to a gas chromatograph. By exploiting the non-destructive nature of the diode array detector, the effluent from the detector was split to two parallel detectors; namely a quadrupole mass spectrometer and a flame ionization detector. This multi-hyphenated configuration with the use of three detectors is a powerful approach not only for selective detection enhancement but also for improvement in structural elucidation of volatile compounds where fewer fragments can be obtained or for isomeric compound analysis. With the diode array detector capable of generating high resolution gas phase spectra, the information collected provides useful confirmatory information without a total dependence on the chromatographic separation process which is based on retention time. This information-rich approach to chromatography is achieved without incurring extra analytical time, resulting in improvements in compound identification accuracy, analytical productivity, and cost. Chromatographic performance obtained from model compounds was found to be acceptable with a relative standard deviation of the retention times of less than 0.01% RSD, and a repeatability at two levels of concentration of 100 and 1000ppm (v/v) of less than 5% (n=10). With this configuration, correlation of data between the three detectors was simplified by having near identical retention times for the analytes studied.

摘要

开发并实施了一种有效的分析策略,以利用三种不同的气相色谱检测器(即紫外光谱、火焰离子化和质谱)的协同作用进行挥发性化合物分析。该策略通过成功地将用户可选的多波长二极管阵列检测器与气相色谱仪联用实现,该检测器具有正温度系数热敏电阻作为等温加热器。利用二极管阵列检测器的非破坏性,将检测器的流出物分流到两个平行的检测器;即四极杆质谱仪和火焰离子化检测器。这种使用三个检测器的多联用法是一种强大的方法,不仅可以增强选择性检测,还可以改善挥发性化合物的结构阐明,因为可以获得较少的碎片,或者进行异构体化合物分析。由于二极管阵列检测器能够生成高分辨率的气相光谱,因此收集的信息提供了有用的确认信息,而无需完全依赖基于保留时间的色谱分离过程。这种信息丰富的色谱方法不会增加额外的分析时间,从而提高了化合物鉴定的准确性、分析效率和成本。从模型化合物获得的色谱性能可以接受,保留时间的相对标准偏差小于 0.01%RSD,在 100 和 1000ppm(v/v)两个浓度水平的重复性小于 5%(n=10)。在这种配置下,通过对研究的分析物具有几乎相同的保留时间,简化了三个检测器之间的数据相关性。