Pinsornsak Piya, Harnroongroj Thos
J Med Assoc Thai. 2016 Nov;99(11):1185-91.
The specialized instrument system used in minimally invasive surgery (MIS) has been developed for reducing soft tissue trauma in total knee arthroplasty (TKA). Compared with front-cutting MIS instruments, side-cutting quadriceps sparing MIS instruments have the advantage of creating a smaller incision and causing fewer traumas to the quadriceps tendon. However, the accuracy of side-cutting instruments concerns surgeons in prosthesis malalignment.
To compare the accuracy of side-cutting quadriceps sparing instruments versus front-cutting instruments in MIS-TKA.
In this prospective randomized controlled study, we compared the accuracy of side-cutting quadriceps sparing instruments versus the front-cutting instruments used in MIS-TKA. Sixty knees were included in the study, with 30 knees in each group. All the operations were performed by single surgeon. Coronal alignment (tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle), and sagittal alignment (femoral component flexion and tibial posterior slope) were measured and compared.
Tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle, all of which are considered in the assessment of acceptable coronal radiographic alignment, were not different between groups (p = 0.353, 0.500, and 0.177, respectively). However, side-cutting quadriceps sparing instruments produced less acceptable sagittal radiographic alignment, femoral component flexion (63% vs. 93%, p = 0.005), and tibial posterior slope (73% vs. 93%, p = 0.04).
Side-cutting quadriceps sparing MIS-TKA instruments had similar accuracy to front-cutting MIS-TKA instruments for coronal alignment but is less accurate for sagittal alignment.
用于微创手术(MIS)的专业器械系统已被开发出来,以减少全膝关节置换术(TKA)中的软组织创伤。与前切式MIS器械相比,侧切式股四头肌保留MIS器械具有切口更小、对股四头肌肌腱造成的创伤更少的优点。然而,侧切器械的准确性使外科医生担心假体排列不齐的问题。
比较侧切式股四头肌保留器械与前切式器械在MIS-TKA中的准确性。
在这项前瞻性随机对照研究中,我们比较了侧切式股四头肌保留器械与用于MIS-TKA的前切式器械的准确性。该研究纳入了60个膝关节,每组30个膝关节。所有手术均由同一位外科医生进行。测量并比较冠状面排列(胫股角、股骨远端外侧角和胫骨近端内侧角)和矢状面排列(股骨组件屈曲和胫骨后倾)。
在评估可接受的冠状位X线片排列时所考虑的胫股角、股骨远端外侧角和胫骨近端内侧角,两组之间没有差异(分别为p = 0.353、0.500和0.177)。然而,侧切式股四头肌保留器械产生的矢状位X线片排列、股骨组件屈曲(63%对93%,p = 0.005)和胫骨后倾(73%对93%,p = 0.04)的可接受性较低。
侧切式股四头肌保留MIS-TKA器械在冠状面排列方面的准确性与前切式MIS-TKA器械相似,但在矢状面排列方面准确性较低。