Suppr超能文献

在埃塞俄比亚的一些选定卫生中心,导致痰涂片抗酸杆菌(AFB)检测质量低下的因素:从质量控制角度来看。

Factors which contributed for low quality sputum smears for the detection of acid fast bacilli (AFB) at selected health centers in Ethiopia: A quality control perspective.

机构信息

Management Science for Health, Addis Ababa, Ethiopia.

West HarargheZonal Health Department, TB and HIV Case Team, Chiro, Ethiopia.

出版信息

PLoS One. 2018 Jun 20;13(6):e0198947. doi: 10.1371/journal.pone.0198947. eCollection 2018.

Abstract

OBJECTIVES

Quality of tuberculosis (TB) microscopy diagnosis is not a guarantee despite implementation of External Quality Assurance (EQA) service in all laboratories of health facilities. Hence, we aimed at evaluating the technical quality and the findings of sputum smear microscopy for acid fast bacilli (AFB) at health centers in Hararge Zone, Oromia Region, Ethiopia.

METHODS

A cross-sectional study was carried out between July 8, 2014 and July 7, 2015.A pre-tested structured questionnaire was used to collect data. Lot Quality Assurance Sampling (LQAS) method was put into practice for collecting all necessary sample slides. Data were analyzed by using SPSS (Statistical Package for Social Sciences) version 20 software. P-value < 0.05 was considered as statistically significant.

RESULTS

Of the total55 health center laboratories which had been assessed during the study period, 20 (36.4%) had major technical errors; 13 (23.6%) had 15 false negative results and 17 (30.9%) had 22 false positive results. Moreover, poor specimen quality, smear size, smear thickness, staining and evenness were indicated in 40 (72.7%), 39 (70.9%), 37 (67.3%), 27(49.1%) and 37 (67.3%) of the collected samples, respectively. False negative AFB findings were significantly associated with lack of Internal Quality Control (IQC) measures (AOR (Adjusted Odds Ratio): 2.90 (95% CI (Confidence Interval): 1.25,6.75) and poor staining procedures (AOR: 2.16(95% CI: 1.01, 5.11).

CONCLUSIONS

The qualities of AFB smear microscopy reading and smearing were low in most of the laboratories of the health centers. Therefore, it is essential to strength EQA program through building the capacity of laboratory professionals.

摘要

目的

尽管在所有卫生机构的实验室都实施了外部质量保证 (EQA) 服务,但结核病 (TB) 显微镜诊断的质量并不能得到保证。因此,我们旨在评估奥罗米亚地区哈拉尔格地区卫生中心的中心实验室的痰涂片抗酸杆菌 (AFB) 镜检技术质量和结果。

方法

本研究为 2014 年 7 月 8 日至 2015 年 7 月 7 日进行的横断面研究。使用经过预测试的结构化问卷收集数据。采用批量质量保证抽样 (LQAS) 方法收集所有必要的样本载玻片。使用 SPSS (社会科学统计软件包) 版本 20 软件分析数据。P 值 < 0.05 被认为具有统计学意义。

结果

在所评估的 55 个卫生中心实验室中,有 20 个(36.4%)存在主要技术错误;13 个(23.6%)有 15 个假阴性结果,17 个(30.9%)有 22 个假阳性结果。此外,在收集的样本中,分别有 40(72.7%)、39(70.9%)、37(67.3%)、27(49.1%)和 37(67.3%)的样本质量差、涂片大小、涂片厚度、染色和均匀性差。缺乏内部质量控制 (IQC) 措施(调整后优势比 (AOR):2.90(95%置信区间 (CI):1.25,6.75)和染色程序差与假阴性 AFB 结果显著相关(AOR:2.16(95%CI:1.01,5.11)。

结论

大多数卫生中心实验室的 AFB 涂片镜检阅读和涂片质量较差。因此,通过加强实验室专业人员的能力来加强 EQA 计划至关重要。