Using finite element analysis, loop response during simulated loop-pulling was determined for plain reversed L- and T-loop configurations at three IBDs and two sizes. Force systems were calculated on both loop ends for two activation forces.
The 12 mm IBD reversed L-loops had almost equal M/F ratios in opposite directions at both ends. A small intrusive force was found at the canine bracket (CB). The 6 mm IBD reversed L-loops showed larger M/F ratios and extrusive forces at the premolar bracket (PB) and smaller M/F with intrusive forces at CB. The force system of 12 mm IBD T-loops showed the similar force systems as off-centered V-bends with extrusive force at CB, whilst plain 6 mm IBD T-loops showed properties similar to centered V-bends with less extrusive force at CB.
Reversed L closing loops placed no extrusive force on the CB end at various IBDs, indicating that reversed loops will generate an intrusive force at anterior teeth during space closure.
前牙托槽上的侵入力有助于避免覆牙合加深。在间隙关闭过程中,反转的普通L形曲可能会产生这种有利的力系统。
在三种托槽间距(IBD)下,将反转L形曲的力系统与T形曲的力系统进行比较。
计算机模拟研究。
采用有限元分析,确定在三种IBD和两种尺寸下,普通反转L形曲和T形曲在模拟拉曲过程中的曲的反应。计算两种激活力下曲两端的力系统。
12 mm IBD的反转L形曲两端在相反方向上的M/F比几乎相等。在尖牙托槽(CB)处发现了一个小的侵入力。6 mm IBD的反转L形曲在第一前磨牙托槽(PB)处显示出更大的M/F比和挤出力,在CB处显示出较小的M/F比和侵入力。12 mm IBD的T形曲的力系统显示出与偏心V形曲类似的力系统,在CB处有挤出力,而普通6 mm IBD的T形曲显示出与中心V形曲类似的特性,在CB处的挤出力较小。
在不同的IBD下,反转L形关闭曲在CB端不会产生挤出力,这表明反转曲在间隙关闭过程中会在前牙产生侵入力。