School of Health, Medicine and Applied Science, Central Queensland University, Bundaberg, QLD, Australia.
School of Health, Medicine and Applied Science, Central Queensland University, Rockhampton, QLD, Australia.
Sports Med. 2018 Sep;48(9):2179-2198. doi: 10.1007/s40279-018-0956-7.
Changes in the mechanical behaviour of the Achilles and patellar tendons in tendinopathy could affect muscle performance, and have implications for injury prevention and rehabilitation strategies.
To determine the effect of clinically diagnosed tendinopathy on the mechanical and material properties of the Achilles tendon (AT) and patellar tendon (PT).
Systematic review with meta-analysis.
A search of electronic databases (SPORTDiscus, CINAHL, PubMed, ScienceDirect and Google Scholar) was conducted to identify research articles that reported local and global in vivo mechanical (e.g. strain, stiffness) and/or material properties (e.g. modulus) of the AT and/or PT in people with and without tendinopathy. Effect sizes and corresponding 95% confidence intervals for individual studies were calculated for tendon strain, stiffness, modulus and cross-sectional area.
Eighteen articles met the inclusion criteria (AT only = 11, PT only = 5, AT and PT = 2). There was consistent evidence that the reported AT strain was higher in people with tendinopathy, compared to asymptomatic controls. People with Achilles tendinopathy had a lower AT global stiffness, lower global modulus and lower local modulus, compared to asymptomatic controls. In contrast, there was no clear and consistent evidence that the global or local mechanical or material properties of the PT are altered in tendinopathy.
The in vivo mechanical and material properties of the Achilles tendon-aponeurosis are altered in tendinopathy, compared to asymptomatic tendons. Despite a similar clinical presentation to Achilles tendinopathy, patellar tendinopathy does not appear to alter the tensile behaviour of the PT in vivo.
跟腱和髌腱在腱病中的力学行为变化可能会影响肌肉功能,并对损伤预防和康复策略有影响。
确定临床诊断的腱病对跟腱(AT)和髌腱(PT)的力学和材料特性的影响。
系统综述和荟萃分析。
检索电子数据库(SPORTDiscus、CINAHL、PubMed、ScienceDirect 和 Google Scholar),以确定报告有和无腱病人群的 AT 和/或 PT 的局部和整体体内力学(例如应变、刚度)和/或材料特性(例如模量)的研究文章。为肌腱应变、刚度、模量和横截面积计算了个别研究的效应量和相应的 95%置信区间。
有 18 篇文章符合纳入标准(仅 AT = 11 篇,仅 PT = 5 篇,AT 和 PT = 2 篇)。有证据表明,与无症状对照组相比,患有腱病的人的跟腱报告的应变更高。与无症状对照组相比,患有跟腱病的人的跟腱整体刚度较低、整体模量和局部模量较低。相比之下,没有明确和一致的证据表明 PT 的整体或局部力学或材料特性在腱病中发生改变。
与无症状肌腱相比,腱病患者的跟腱-腱膜的体内力学和材料特性发生改变。尽管与跟腱病有相似的临床表现,但髌腱病似乎不会改变体内 PT 的拉伸行为。