Abstract

This in vitro study evaluated the marginal microleakage of composite inlays luted with 3 different cement systems. The null hypothesis was that the luting materials would not influence dye penetration, showing the same degree of microleakage. Thirty-six sound molars were selected, mesio-occlusodistal cavities were prepared, and the teeth were randomly divided into 3 groups (n = 12). Composite resin inlay restorations were made and cemented using a dual-curing resin cement (Calibra), a light-curing flowable composite (Charisma Flow), or a self-adhesive resin cement (RelyX Unicem). The restored teeth were subjected to fatigue cycles and immersed in 0.5% basic fuchsin dye for 24 hours. Two orthogonal cuts were made to enable evaluation of dye penetration at the cervical and occlusal margins. The sections were evaluated with a 4-point scale ranging from 0 (no penetration) to 3 (penetration up to the cavity floor [occlusal margins] or axial wall [cervical margins]). The Calibra and Charisma Flow groups showed greater microleakage, notably at the cervical margins, whereas RelyX Unicem specimens showed the least dye penetration. Significant differences were found between the Calibra and Charisma Flow groups and between the Charisma Flow and RelyX Unicem groups (P < 0.05). No statistically significant differences were detected between the Calibra and RelyX Unicem groups. The microleakage associated with the flowable composite was significantly greater than that associated with both resin cements, results that discourage its use for luting of Class II composite inlays.

摘要

这项体外研究评估了用3种不同粘结剂系统粘结的复合树脂嵌体的边缘微渗漏情况。无效假设是粘结材料不会影响染料渗透,即显示相同程度的微渗漏。选取36颗完好的磨牙,制备近中-咬合-远中窝洞,然后将牙齿随机分为3组(每组n = 12)。制作复合树脂嵌体修复体,并分别使用双固化树脂粘结剂(Calibra)、光固化可流动复合树脂(Charisma Flow)或自粘结树脂粘结剂(RelyX Unicem)进行粘结。将修复后的牙齿进行疲劳循环处理,然后浸泡在0.5%碱性品红染料中24小时。制作两个正交切片,以便评估颈部和咬合边缘的染料渗透情况。切片采用4级评分标准进行评估,从0(无渗透)到3(渗透至洞底[咬合边缘]或轴壁[颈部边缘])。Calibra组和Charisma Flow组显示出更大的微渗漏,尤其是在颈部边缘,而RelyX Unicem组的标本显示出最少的染料渗透。Calibra组和Charisma Flow组之间以及Charisma Flow组和RelyX Unicem组之间存在显著差异(P < 0.05)。Calibra组和RelyX Unicem组之间未检测到统计学上的显著差异。与可流动复合树脂相关的微渗漏明显大于与两种树脂粘结剂相关的微渗漏,这一结果不建议将其用于粘结II类复合树脂嵌体。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验