• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Vertical Distribution Characteristics of Fe and Mn in Subtropical Reservoirs During Summer].

作者信息

Yang Si-Yuan, Zhao Jian, Yu Hua-Zhang, Peng Liang, Xiao Li-Juan

机构信息

Institute of Hydrobiology, Jinan University, Guangzhou 510632, China.

Shantou Suboffice, Hydrological Bureau of Guangdong Province, Shantou 515041, China.

出版信息

Huan Jing Ke Xue. 2017 Nov 8;38(11):4546-4552. doi: 10.13227/j.hjkx.201704233.

DOI:10.13227/j.hjkx.201704233
PMID:29965397
Abstract

Iron (Fe) and manganese (Mn) are redox-sensitive elements that are both important chemical indicators of water quality. To study their vertical distribution characteristics in south-subtropical reservoirs during summer, Fe and Mn concentrations in the water column, as well as the physical and chemical conditions of the water, were investigated in the lacustrine zones of nine reservoirs in the eastern of Guangdong Province, in July 2016. These results showed that Fe and Mn exhibited a strong concentration gradient in deep reservoirs due to thermal stratification. The total Fe (TFe), total Mn (TMn), dissolved Fe (DFe), and dissolved Mn (DMn) concentrations in the surface water are significantly lower than in these in bottom zones (TFe, =6.708, =0.032; TMn, =9.720, =0.014; DFe, =8.129, =0.029; DMn, =11.125, =0.016). The average concentrations of TFe and TMn are 0.399 mg·L and 0.422 mg·L, respectively at the bottom five of the deep reservoirs, and the dissolved ions accounted for more than 70% of this concentration. In shallow reservoirs without thermal stratification, TFe, TMn, DFe and DMn concentrations in surface water are lower than those measured at bottom of the reservoir, no significant difference was detected (TFe, =0.135, =0.726; TMn, =0, =1; DFe, =0.006, =0.943; DMn, =0.007, =0.936). The average concentrations of TFe and TMn are 0.110 mg·L and 0.089 mg·L, respectively at the bottom of the four shallow reservoirs, and they were present predominantly in particulate form. The concentrations of TFe and DFe correlated significantly (<0.05) with the dissolved oxygen (DO) concentration, pH and depth, but did not significantly correlate with TN or TP concentration in the deep reservoirs. The gradient distributions of DO and pH levels is critical to the gradient distribution of Fe and Mn in deep reservoirs because of water stratification. Low DO concentrations and acidic conditions in these areas contributed to the release of Fe and Mn from sediment and result in high dissociation of these elements in the bottom of deep reservoirs. Simultaneously, high concentrations of Fe and Mn at the bottom of reservoirs may also attribute to the characteristic red soil of this region. The results from this study imply that the high concentrations of Fe and Mn common in the bottom of deep reservoirs is associated with the stable stratification of these reservoirs in the summer. The concentrations of Fe and Mn may be exceed water standards when deep water is taken for public water provision. The problem may be avoided with surface water supplying.

摘要

相似文献

1
[Vertical Distribution Characteristics of Fe and Mn in Subtropical Reservoirs During Summer].
Huan Jing Ke Xue. 2017 Nov 8;38(11):4546-4552. doi: 10.13227/j.hjkx.201704233.
2
Evidences of strong sources of DFe and DMn in Ryder Bay, Western Antarctic Peninsula.南极半岛西部莱德湾存在强溶解性铁和溶解性锰来源的证据。
Philos Trans A Math Phys Eng Sci. 2018 Jun 28;376(2122). doi: 10.1098/rsta.2017.0172.
3
Controlling reduced iron and manganese in a drinking water reservoir by hypolimnetic aeration and artificial destratification.通过底层曝气和人工分层控制饮用水库中的还原铁和锰。
Sci Total Environ. 2019 Oct 1;685:497-507. doi: 10.1016/j.scitotenv.2019.05.445. Epub 2019 May 30.
4
Controlling soluble iron and manganese in a water-supply reservoir using hypolimnetic oxygenation.利用下层水体充氧控制供水水库中的可溶性铁和锰。
Water Res. 2009 Mar;43(5):1285-94. doi: 10.1016/j.watres.2008.12.019. Epub 2008 Dec 25.
5
Insight into atmospheric deposition and spatial distribution of bioavailable iron in the glaciers of northeastern Tibetan Plateau.青藏高原东北部冰川中生物可利用铁的大气沉降及空间分布洞察
Sci Total Environ. 2022 Jun 15;825:153946. doi: 10.1016/j.scitotenv.2022.153946. Epub 2022 Feb 18.
6
[Distribution Characteristics and Migration Rules of Pollutants in Sediments of Reservoirs with Plantation, Southern China].[中国南方种植区水库沉积物中污染物的分布特征及迁移规律]
Huan Jing Ke Xue. 2020 May 8;41(5):2247-2256. doi: 10.13227/j.hjkx.201909255.
7
Stability of dissolved and soluble Fe(II) in shelf sediment pore waters and release to an oxic water column.溶解态和可溶态Fe(II)在陆架沉积物孔隙水中的稳定性及其向含氧水柱的释放
Biogeochemistry. 2017;135(1):49-67. doi: 10.1007/s10533-017-0309-x. Epub 2017 Feb 27.
8
Effectiveness of hypolimnetic oxygenation for preventing accumulation of Fe and Mn in a drinking water reservoir.底泥增氧防止饮用水库中铁和锰积累的效果。
Water Res. 2016 Dec 1;106:1-14. doi: 10.1016/j.watres.2016.09.038. Epub 2016 Sep 20.
9
Effects of nitrate addition on water column methylmercury in Occoquan Reservoir, Virginia, USA.硝酸盐添加对美国弗吉尼亚 Occoquan 水库水柱甲基汞的影响。
Water Res. 2017 Mar 1;110:288-296. doi: 10.1016/j.watres.2016.12.022. Epub 2016 Dec 18.
10
[Analysis on the variation characteristics of iron and manganese concentration and its genesis in Changtan Reservoir in Taizhou, Zhejiang Province].[浙江台州长潭水库铁锰含量变化特征及其成因分析]
Huan Jing Ke Xue. 2014 Oct;35(10):3702-8.

引用本文的文献

1
Derivation of a Freshwater Quality Benchmark and an Ecological Risk Assessment of Ferric Iron in China.中国淡水水质基准的推导及三价铁的生态风险评估
Toxics. 2025 Jun 4;13(6):475. doi: 10.3390/toxics13060475.