Suppr超能文献

一种定量 gag 反射测量方法的可靠性、有效性及性别差异。

Reliability, validity, and sex differences in a quantitative gag reflex measurement method.

作者信息

Karibe Hiroyuki, Okamoto Ayuko, Kato Yuichi, Shimazu Kisaki, Goddard Greg

机构信息

Department of Pediatric Dentistry, School of Life Dentistry, Nippon Dental University, Tokyo, Japan.

Department of Oral Maxillofacial Surgery, Center for Orofacial Pain, University of California San Francisco, San Francisco, California.

出版信息

J Oral Rehabil. 2018 Oct;45(10):798-804. doi: 10.1111/joor.12687. Epub 2018 Jul 17.

Abstract

A reliable assessment method is required to manage the gag reflex. We tested the inter- and intra-examiner reliability and validity of a quantitative measurement method and evaluated the differences between sexes. This study included 21 healthy adults (10 women, 11 men; mean age, 27.1 ± 9.9 years). An examiner inserted a standard saliva ejector slowly down the participant's throat to determine the maximum tolerance of the gag reflex; the insertion depth was used as an index of gag reflex. The reflex was measured by one examiner during two sessions (S1 and S3) and by a second examiner during one session (S2) under the same conditions. The galvanic skin response (GSR) and heart rate (HR) were recorded during each session to test the method validity. Data were analysed using the intraclass correlation coefficient (ICC), paired t test, and two-way repeated-measures analysis of variance. The ICC of the gag reflex measurements was 0.91 between S1 and S2, and 0.93 between S1 and S3. The GSR and HR increased significantly after the maximum tolerance of the reflex in S1, S2, and S3 (GSR: P < 0.001, P = 0.004, P = 0.001, respectively; HR: all, P < 0.001). Differences in the measurements according to sex and session were not significant. Our method exhibited excellent inter- and intra-examiner reliability and was unaffected by the participants' sex. Measurement revealed significant autonomic reactivity, which is common for this reflex. Consequently, this method may be used in clinical and laboratory-based applications.

摘要

需要一种可靠的评估方法来管理咽反射。我们测试了一种定量测量方法在检查者之间和检查者内部的可靠性和有效性,并评估了性别差异。本研究纳入了21名健康成年人(10名女性,11名男性;平均年龄27.1±9.9岁)。一名检查者将标准唾液吸引器缓慢插入参与者的喉咙,以确定咽反射的最大耐受程度;插入深度用作咽反射的指标。在相同条件下,由一名检查者在两个阶段(S1和S3)进行测量,另一名检查者在一个阶段(S2)进行测量。在每个阶段记录皮肤电反应(GSR)和心率(HR)以测试该方法的有效性。使用组内相关系数(ICC)、配对t检验和双向重复测量方差分析对数据进行分析。S1和S2之间咽反射测量的ICC为0.91,S1和S3之间为0.93。在S1、S2和S3中,反射的最大耐受程度出现后,GSR和HR显著增加(GSR:分别为P<0.001、P = 0.004、P = 0.001;HR:均为P<0.001)。根据性别和阶段的测量差异不显著。我们的方法在检查者之间和检查者内部均表现出出色的可靠性,且不受参与者性别的影响。测量显示出显著的自主反应性,这是该反射常见的情况。因此,该方法可用于临床和基于实验室的应用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验