Minissale Marco, Zanon-Willette Thomas, Prokhorov Ivan, Elandaloussi Hadj, Janssen Christof
IEEE Trans Ultrason Ferroelectr Freq Control. 2018 Aug;65(8):1487-1491. doi: 10.1109/TUFFC.2018.2843183. Epub 2018 Jun 1.
Tunable electromagnetic (EM) sources, such as voltage-controlled oscillators, micro-electromechanical systems, or diode lasers are often required to be linear during frequency-sweep modulation. In many cases, it might also be sufficient that the degree of the nonlinearity can be well controlled. Without further efforts, these conditions are rarely achieved using free-running sources. Based on a predistortion voltage ramp, we develop in this paper a simple and universal method that minimizes the nonlinear frequency response of tunable EM sources. Using a current-driven quantum cascade laser as an example, we demonstrate that the nonlinearity can easily be reduced by a factor of ten when using a single distortion parameter . In the investigation of the IR absorption spectrum of ozone at 10 , an even better reduction of the frequency-scale error by two orders of magnitude is obtained by using the predistortion method to generate an essentially purely quadratic sweep frequency dependence that can be inverted easily to retrieve precise molecular line positions. After having tested our method on a variety of EM sources, we anticipate a wide range of applications in a variety of fields.
可调谐电磁(EM)源,如压控振荡器、微机电系统或二极管激光器,在扫频调制期间通常需要是线性的。在许多情况下,非线性程度能够得到很好的控制可能也就足够了。如果不做进一步的努力,使用自由运行的源很少能达到这些条件。基于预失真电压斜坡,我们在本文中开发了一种简单通用的方法,该方法可将可调谐EM源的非线性频率响应降至最低。以电流驱动的量子级联激光器为例,我们证明,当使用单个失真参数时,非线性可以很容易地降低到原来的十分之一。在对10处臭氧的红外吸收光谱进行研究时,通过使用预失真方法生成基本纯二次方的扫频依赖性,这种依赖性可以很容易地反转以检索精确的分子谱线位置,频率尺度误差能更好地降低两个数量级。在对各种EM源测试了我们的方法之后,我们预计该方法将在各种领域有广泛的应用。