Aljawder Abdulla, Alomran Dana, Alayyoub Mohammed, Alkhalifa Fahad
Bahrain Defense Force Royal Medical Services, Orthopedic Specialist, Orthopedic Department, Alriffa, Bahrain.
Bahrain Defense Force Royal Medical Services, Orthopedic Resident, Orthopedic Department, Alriffa, Bahrain.
Open Orthop J. 2018 May 31;12:173-179. doi: 10.2174/1874325001812010173. eCollection 2018.
Total Knee Replacement (TKR) is one of the most commonly performed orthopaedic surgery(1). Immediate postoperative portable radiographs are performed after primary TKR in order to identify any potential complications and technical flaws. It also serves as a reference for comparison with subsequent radiographs. The aim of this study was to evaluate the clinical and economical value of these radiographs in TKR. It compares the quality of the portable radiograph, taken immediately post-operation, with in-suite radiographs taken 5-7 weeks post-operation.
In this retrospective study, a consecutive series of 389 TKR patients from January-2011 to March-2015 were reviewed. Radiological evaluation consisted of assessing the beam angle and the exposure on the images. Implant positioning was also compared by measuring the anatomical axis to look for component alignment discrepancies.
The quality of the portable recovery room radiograph was overall inferior to the radiology suite radiograph regarding both beam angle and exposure. Component alignment discrepancies were also identified in the angle measurements between both types of radiographs.
Therefore, our study demonstrated that there is no clinical or financial value obtained from postoperative portable radiograph. Furthermore, Immediate recovery room radiographs should be avoided from being performed routinely and may only be used in cases where the surgeon is utilizing a new implant or technique. No external funding was provided for this study from any source.
全膝关节置换术(TKR)是最常开展的骨科手术之一。初次全膝关节置换术后需进行术后即时便携式X线摄影,以识别任何潜在并发症和技术缺陷。它还可作为与后续X线片进行对比的参考。本研究的目的是评估这些X线片在全膝关节置换术中的临床和经济价值。将术后即时拍摄的便携式X线片的质量与术后5 - 7周在手术室拍摄的X线片的质量进行比较。
在这项回顾性研究中,对2011年1月至2015年3月连续收治的389例全膝关节置换术患者进行了评估。影像学评估包括评估图像上的射线角度和曝光情况。还通过测量解剖轴来比较植入物位置,以查找组件对齐差异。
就射线角度和曝光而言,便携式恢复室X线片的质量总体上不如放射科X线片。在两种类型X线片的角度测量中也发现了组件对齐差异。
因此,我们的研究表明术后便携式X线片没有临床或经济价值。此外,应避免常规进行术后即时恢复室X线摄影,仅在外科医生使用新植入物或新技术的情况下才可使用。本研究未获得任何来源的外部资金。