• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror].

作者信息

Lü Jin-guang, Liang Jing-qiu, Liang Zhong-zhu, Tian Chao, Qin Yu-xin

出版信息

Guang Pu Xue Yu Guang Pu Fen Xi. 2016 May;36(5):1554-9.

PMID:30001062
Abstract

To realize the static state and high throughput of Fourier transform imaging spectrometer (FTIS), a temporal spatial mixed modulated FTIS based on multi-micro-mirror was put forward in this paper, whose interference system was based on Michelson interferometer with a multi-micro-mirror to replace the plane mirror. The remarkable characteristics of this FTIS were no movable parts and slit existing in this system, and the interferogram and image of object could be gained at the same time. The fore-optics system imaged the object on the plane mirror and multi-micro-mirror of the interference system, due to the structure feature of multi-micro-mirror, the optical path difference (OPD) of two imaging beam could be modulated. Through the reimaging system, the image of object with different interference order could be obtained. By means of the analysis to the spectrum signal-to-noise ratio (SNR) of interference system, the relationship between spectrum SNR and image SNR was definite, and the characteristic parameters of multi-micro-mirror were determined. To ensure the constancy of OPD corresponding to each step plane, by means of the analysis to the imaging process of fore-optics system, the optical path structure of telecentric in image space was determined. According to the calculation of the relationship between field of view and OPD, the design indexes of fore-optics system were determined and the optical design was completed. To ensure no extra OPD was introduced by reimaging system, through the analysis of the imaging feature by reimaging system, the optical path structure of double telecentric was determined. According to the calculation of the relationship between incidence aperture angle and step number, the optical system that satisfied the system requirement was designed. By means of the theory analysis and optical design to each unit system, this research can provide a novel development strategy for static and high throughput FTIS.

摘要

相似文献

1
[Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror].
Guang Pu Xue Yu Guang Pu Fen Xi. 2016 May;36(5):1554-9.
2
[Study on uniformity of optical field in static Fourier transform spectrometer].[静态傅里叶变换光谱仪光场均匀性研究]
Guang Pu Xue Yu Guang Pu Fen Xi. 2012 Jan;32(1):259-63.
3
[The optimizing design and experiment for a MOEMS micro-mirror spectrometer].[一种微机电系统(MOEMS)微镜光谱仪的优化设计与实验]
Guang Pu Xue Yu Guang Pu Fen Xi. 2011 Dec;31(12):3412-6.
4
[Comparison of correction methods for nonlinear optic path difference of reflecting rotating Fourier transform spectrometer].[反射式旋转傅里叶变换光谱仪非线性光程差校正方法比较]
Guang Pu Xue Yu Guang Pu Fen Xi. 2010 Jun;30(6):1678-82.
5
[Manufacture tolerance analysis of solid Mach-Zehnder interferometer in large aperture static imaging spectrometer (LASIS)].大口径静态成像光谱仪(LASIS)中固体马赫-曾德尔干涉仪的制造公差分析
Guang Pu Xue Yu Guang Pu Fen Xi. 2014 Jul;34(7):2000-4.
6
Design of spatio-temporally modulated static infrared imaging Fourier transform spectrometer.时空调制静态红外成像傅里叶变换光谱仪的设计
Opt Lett. 2014 Aug 15;39(16):4911-4. doi: 10.1364/OL.39.004911.
7
[The principle and analysis of micro-Fourier transform spectrometer based on MEMS micro-mirror].基于MEMS微镜的微型傅里叶变换光谱仪原理与分析
Guang Pu Xue Yu Guang Pu Fen Xi. 2012 Nov;32(11):3151-4.
8
Assembly and alignment method for optimized spatial resolution of off-axis three-mirror fore optics of hyperspectral imager.用于高光谱成像仪离轴三镜前光学系统优化空间分辨率的装配与对准方法
Opt Express. 2017 Aug 21;25(17):20817-20828. doi: 10.1364/OE.25.020817.
9
Moving corner-cube mirror interferometer and reflection characteristic of corner-cube mirror.
Appl Opt. 2010 Jul 20;49(21):4088-95. doi: 10.1364/AO.49.004088.
10
[Study on spectrum inversion of spatially modulated Fourier transform spectrometer].[空间调制傅里叶变换光谱仪的光谱反演研究]
Guang Pu Xue Yu Guang Pu Fen Xi. 2012 Jun;32(6):1694-9.