Suppr超能文献

角膜交联治疗圆锥角膜一年后的角膜光学性能。

Optical Performance of the Cornea One Year Following Keratoconus Treatment with Corneal Collagen Cross-Linking.

机构信息

a Department of Ophthalmology , Yıldırım Beyazıt University, Atatürk Training and Research Hospital , Ankara , Turkey.

出版信息

Curr Eye Res. 2018 Dec;43(12):1415-1421. doi: 10.1080/02713683.2018.1501802. Epub 2018 Jul 30.

Abstract

PURPOSE

The purpose of the study is to assess changes in optical performance of the cornea in patients with keratoconus following treatment with corneal collagen crosslinking (CXL).

MATERIALS AND METHODS

One hundred and eleven eyes of 111 consecutive keratoconus patients with 12-month follow-up after CXL were included. The changes in the visual acuity, manifest refractive errors, and corneal topographic parameters were evaluated. Sirius dual-scanning corneal tomography was used to determine the effectiveness of CXL on each patient's total corneal optical quality; preoperative and 12-month postoperative measurements were analyzed over a 4-mm stimulated pupil and were compared with regards to higher order corneal aberrations (total amount of higher order aberrations [HOAs], vertical coma, horizontal coma, vertical trefoil, oblique trefoil, and spherical aberration), vertical and horizontal modulation transfer function (MTF), and Strehl ratio of point spread function (PSF).

RESULTS

At 12 months, there was a significant improvement in mean uncorrected visual acuity (UCVA) (P < 0.001), best corrected visual acuity (BCVA) (P < 0.001), spherical equivalent refraction (P = 0.007), and manifest astigmatic refraction (P < 0.001). The corneal topographic measurements revealed a significant decrease in the mean simulated keratometry-1, simulated keratometry -2, and maximum keratometry compared with the baseline measurements (P < 0.001, for all). In addition, there were significant improvements in mean root mean square error values for corneal total HOA (P < 0.001), vertical coma (P < 0.001), and vertical trefoil (P = 0.008) following CXL. Mean MTF and Strehl ratio did not change after CXL (P > 0.05). The improvement in UCVA significantly correlated with the changes in vertical trefoil (r = -0.191, P = 0.044), and the improvement in BCVA and the changes in manifest astigmatic correction were also significantly correlated (r = -0.247, P = 0.009) 12 months after CXL.

CONCLUSIONS

CXL treatment for keratoconus led to an improvement in visual, refractive, topographic, and most corneal HOAs outcomes at the 12-month follow-up. However, these improvements were not enough to increase corneal MTF and the Strehl ratio of PSF.

摘要

目的

本研究旨在评估角膜交联(CXL)治疗后圆锥角膜患者角膜光性能的变化。

材料和方法

纳入了 111 例连续接受 CXL 治疗的圆锥角膜患者的 111 只眼,随访 12 个月。评估了视力、显性屈光不正和角膜地形图参数的变化。使用 Sirius 双扫描角膜断层扫描仪来确定 CXL 对每位患者总角膜光学质量的影响;对术前和术后 12 个月的 4mm 刺激瞳孔进行测量,并分析高阶角膜像差(高阶像差总量、垂直彗差、水平彗差、垂直三叶草、斜三叶草和球差)、垂直和水平调制传递函数(MTF)以及点扩散函数(PSF)的斯特列尔比。

结果

在 12 个月时,平均未矫正视力(UCVA)(P<0.001)、最佳矫正视力(BCVA)(P<0.001)、球镜等效屈光度(P=0.007)和显性散光屈光度(P<0.001)均有显著改善。角膜地形图测量显示,与基线测量相比,平均模拟角膜曲率-1、模拟角膜曲率-2 和最大角膜曲率均显著降低(P<0.001,均)。此外,CXL 后角膜总高阶像差(P<0.001)、垂直彗差(P<0.001)和垂直三叶草(P=0.008)的平均均方根误差值均有显著改善。CXL 后平均 MTF 和斯特列尔比没有变化(P>0.05)。UCVA 的改善与垂直三叶草的变化显著相关(r=-0.191,P=0.044),BCVA 的改善与显性散光矫正的变化也显著相关(r=-0.247,P=0.009),均在 CXL 后 12 个月。

结论

CXL 治疗圆锥角膜可在 12 个月随访时改善视力、屈光不正、地形图和大多数角膜高阶像差的结果。然而,这些改善不足以提高角膜 MTF 和 PSF 的斯特列尔比。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验