To compare the visual outcomes and complications between nanothin Descemet stripping automated endothelial keratoplasty (NT-DSAEK) and Descemet membrane endothelial keratoplasty (DMEK).
A prospective comparative case series of 28 consecutive cases of NT-DSAEK (less than or equal to 50 μm) and DMEK was undertaken. Inclusion criteria were a diagnosis of Fuchs dystrophy, presence of pseudophakia, or planned combined cataract surgery/endothelial keratoplasty, with a minimum of 6-month follow-up. Exclusion criteria were any concurrent ocular comorbidities. Primary outcomes measures were best spectacle-corrected visual acuity (BSCVA) and complications.
Mean thickness of NT-DSAEK grafts was 41.0 ± 7.5 μm (range 26-50 μm). At 1 month postoperatively, the DMEK group had significantly better mean BSCVA of 0.18 ± 0.20 logarithm of the minimum angle of resolution (logMAR) (20/33) compared with 0.28 ± 0.16 logMAR (20/40) for NT-NSAEK (P = 0.049). At 3, 6, and 12 months postoperatively, mean BSCVA was comparable between both groups [3 months: NT-DSAEK 0.17 ± 0.12 logMAR (20/30) versus DMEK 0.13 ± 0.17 (20/27), P = 0.31; 6 months: NT-DSAEK 0.11 ± 0.10 logMAR (20/26) versus DMEK 0.09 ± 0.10 (20/25), P = 0.63; 12 months: NT-DSAEK 0.07 ± 0.09 logMAR (20/24) versus DMEK 0.07 ± 0.11 logMAR (20/24), P = 0.95]. Other than 1 NT-DSAEK graft that was successfully rebubbled, no other complications were encountered in either group.
Compared with DMEK, NT-DSAEK provides comparable visual outcomes and complications rates.
比较超薄Descemet膜剥除自动内皮角膜移植术(NT-DSAEK)和Descemet膜内皮角膜移植术(DMEK)的视觉效果和并发症。
对28例连续的NT-DSAEK(小于或等于50μm)和DMEK病例进行前瞻性比较病例系列研究。纳入标准为诊断为Fuchs角膜内皮营养不良、存在人工晶状体或计划进行联合白内障手术/内皮角膜移植术,且至少随访6个月。排除标准为任何并发的眼部合并症。主要观察指标为最佳矫正视力(BSCVA)和并发症。
NT-DSAEK移植物的平均厚度为41.0±7.5μm(范围26 - 50μm)。术后1个月,DMEK组的平均BSCVA明显更好,最小分辨角对数(logMAR)为0.18±0.20(20/33),而NT-NSAEK组为0.28±0.16 logMAR(20/40)(P = 0.049)。术后3、6和12个月,两组的平均BSCVA相当[3个月:NT-DSAEK为0.17±0.12 logMAR(20/30),DMEK为0.13±0.17(20/27),P = 0.31;6个月:NT-DSAEK为0.11±0.10 logMAR(20/26),DMEK为0.09±0.10(20/25),P = 0.63;12个月:NT-DSAEK为0.07±0.09 logMAR(20/24),DMEK为0.07±0.11 logMAR(20/24),P = 0.95]。除1例成功再次注气的NT-DSAEK移植物外,两组均未出现其他并发症。