Ji Misuk, Hur Mina, Moon Hee-Won, Park Mikyoung, Yun Yeo-Min, Lee Sang-Heon
a Department of Laboratory Medicine , Veterans Health Service (VHS) Medical Center , Seoul , Korea.
b Department of Laboratory Medicine , Konkuk University School of Medicine , Seoul , Korea.
Scand J Clin Lab Invest. 2018 Oct;78(6):477-482. doi: 10.1080/00365513.2018.1499957. Epub 2018 Aug 3.
Anti-cyclic citrullinated peptide antibodies (anti-CCPs) are important diagnostic markers for rheumatoid arthritis (RA). We evaluated the analytical and clinical performance of the QUANTA Flash CCP3 (INOVA Diagnostics, USA), a fully automated third-generation anti-CCP assay, in comparison with three second-generation anti-CCP (CCP2) assays. A total of 300 sera (67 from RA patients, 64 from other rheumatic diseases, 43 from osteoarthritis [OA], and 126 from other conditions) were tested with QUANTA Flash CCP3, Kallestad Anti-CCP II (Bio-Rad, USA), Elecsys Anti-CCP (Roche Diagnostics GmbH, Germany), and ARCHITECT Anti-CCP (Abbott Diagnostics, USA). Within-run and total imprecision (% coefficient of variation) of the QUANTA Flash CCP3 were <6%, and its linearity was acceptable over the claimed range (4.0-2,749.7 chemiluminescent units). The frequency of anti-CCP was similar between QUANTA Flash CCP3 and the other CCP2 assays in the RA (67.2% vs. 62.7-70.1%), other rheumatic diseases (7.8% vs. 6.3%), and OA (2.3% vs. 0-2.3%) groups. The concordance rate between QUANTA Flash CCP3 and the other assays ranged from 96.3% to 97.7% (kappa from 0.87 to 0.92). For the diagnosis of RA, the sensitivity/specificity was 67.2%/95.7%, 62.7%/98.3%, 70.2%/96.6%, and 67.2%/97.9%, and the areas under the receiver operating characteristic curves were 0.851, 0.791, 0.853, and 0.867 for QUANTA Flash CCP3, Kallestad, Elecsys, and ARCHITECT assays, respectively. The performance of the QUANTA Flash CCP3 was satisfactory and comparable to that of the three CCP2 assays. This fully automated assay would be a practical and reasonable option in clinical laboratories.
抗环瓜氨酸肽抗体(抗CCP抗体)是类风湿性关节炎(RA)的重要诊断标志物。我们评估了全自动第三代抗CCP检测试剂QUANTA Flash CCP3(美国INOVA诊断公司)的分析性能和临床性能,并与三种第二代抗CCP(CCP2)检测试剂进行了比较。使用QUANTA Flash CCP3、Kallestad抗CCP II(美国伯乐公司)、Elecsys抗CCP(德国罗氏诊断有限公司)和ARCHITECT抗CCP(美国雅培诊断公司)对总共300份血清样本(67份来自RA患者,64份来自其他风湿性疾病患者,43份来自骨关节炎[OA]患者,126份来自其他情况的患者)进行了检测。QUANTA Flash CCP3的批内和总不精密度(变异系数百分比)均<6%,并且在其声称的范围内(4.0 - 2749.7化学发光单位)线性良好。在RA组(67.2%对62.7% - 70.1%)、其他风湿性疾病组(7.8%对6.3%)和OA组(2.3%对0 - 2.3%)中,QUANTA Flash CCP3与其他CCP2检测试剂的抗CCP阳性率相似。QUANTA Flash CCP3与其他检测试剂之间的一致性率在96.3%至97.7%之间(kappa值在0.87至0.92之间)。对于RA的诊断,QUANTA Flash CCP3、Kallestad、Elecsys和ARCHITECT检测试剂的灵敏度/特异性分别为67.2%/95.7%、62.7%/98.3%、70.2%/96.6%和67.2%/97.9%,其受试者工作特征曲线下面积分别为0.851、0.791、0.853和0.867。QUANTA Flash CCP3的性能令人满意,与三种CCP2检测试剂相当。这种全自动检测试剂在临床实验室中将是一种实用且合理的选择。