Suppr超能文献

应用 Tc-99m 亚甲基二膦酸盐 SPECT/CT 扫描,对正常骨盆进行 SUV 测量的回顾性研究。

A retrospective study of SPECT/CT scans using SUV measurement of the normal pelvis with Tc-99m methylene diphosphonate.

机构信息

Department of Medical Image, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.

Department of Medical Image, The Affiliated Hospital of Shaanxi University of Chinese Medicine, Shaanxi, China.

出版信息

J Xray Sci Technol. 2018;26(6):895-908. doi: 10.3233/XST-180391.

Abstract

OBJECTIVE

To perform quantitative measurement based on the standardized uptake value (SUV) of Tc-99m methylene diphosphonate (MDP) in the normal pelvis using a single-photon emission tomography (SPECT)/computed tomography (CT) scanner.

MATERIAL AND METHODS

This retrospective study was performed on 31 patients with cancer undergoing bone SPECT/CT scans with 99mTc-MDP. SUVmax and SUVmean of the normal pelvis were calculated based on the body weight. SUVmax and SUVmean of the bilateral anterior superior iliac spine, posterior superior iliac spine, facies auricularis ossis ilii, ischial tuberosity, and sacrum were also calculated. Furthermore, the correlation of SUVmax and SUVmean of all parts of pelvis with weight, height, and CT was assessed.

RESULTS

The data for 31 patients (20 women and 11 men; mean age 58.97±9.12 years; age range 37-87 years) were collected. SUVmax and SUVmean changed from 1.65±0.40 to 3.8±1.0 and from 1.15±0.25 to 2.07±0.58, respectively. The coefficient of variation of SUVmax and SUVmean ranged from 0.22 to 0.31. SUVmax and SUVmean had no statistically significant difference between men and women. SUVmax and SUVmean also showed no significant correlation with weight and height. However, part of SUVmax and SUVmean showed a significant correlation with CT. In addition, SUVmax and SUVmean of the bilateral ischial tuberosity showed a significant correlation with CT values.

CONCLUSIONS

Determination of the SUV value of the normal pelvis with 99m Tc-MDP SPECT/CT is feasible and highly reproducible. SUVs of the normal pelvis showed a relatively large variability. As a quantitative imaging biomarker, SUVs might require standardization with adequate reference data for the participant to minimize variability.

摘要

目的

使用单光子发射型计算机断层扫描仪(SPECT)/计算机断层扫描(CT)对 99mTc-亚甲基二膦酸盐(MDP)的标准摄取值(SUV)进行定量测量。

材料与方法

对 31 例接受 99mTc-MDP 骨 SPECT/CT 扫描的癌症患者进行回顾性研究。根据体重计算正常骨盆 SUVmax 和 SUVmean。还计算了双侧髂前上棘、髂后上棘、耳状面、坐骨结节和骶骨的 SUVmax 和 SUVmean。此外,评估了所有骨盆部位 SUVmax 和 SUVmean 与体重、身高和 CT 的相关性。

结果

共收集了 31 例患者(20 例女性,11 例男性;平均年龄 58.97±9.12 岁;年龄范围 37-87 岁)的数据。SUVmax 和 SUVmean 分别从 1.65±0.40 增加到 3.8±1.0 和从 1.15±0.25 增加到 2.07±0.58。SUVmax 和 SUVmean 的变异系数范围为 0.22 至 0.31。男性和女性之间 SUVmax 和 SUVmean 无统计学差异。SUVmax 和 SUVmean 与体重和身高也无显著相关性。然而,部分 SUVmax 和 SUVmean 与 CT 值存在显著相关性。此外,双侧坐骨结节的 SUVmax 和 SUVmean 与 CT 值具有显著相关性。

结论

使用 99mTc-MDP SPECT/CT 测定正常骨盆 SUV 值是可行的,且重复性高。正常骨盆 SUV 值的变异性较大。作为一种定量成像生物标志物,SUV 值可能需要与参与者的充足参考数据进行标准化,以最小化变异性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验