Liu Zhenqi, Qiu Shunchen, Gu Yiqun, Ning Meiying
Science and Technology Research Center for Reproductive Health, National Research Institute for Family Planning, Beijing, China.
Biomed Chromatogr. 2018 Dec;32(12):e4367. doi: 10.1002/bmc.4367. Epub 2018 Sep 10.
A specific and sensitive high-performance liquid chromatography-tandem mass spectrometry method that could be used to determine the concentration of levonorgestrel (LNG) in beagle dog plasma was developed. Specifically, terfenadine was used as the internal standard (IS). The separation was achieved on a Kinetex-C 110A column (3 × 30 mm i.d., 2.6 um, Phenomenex) and a gradient mobile phase consists of methanol (0.1% formic acid) and water (0.1% formic acid) was used. The flow rate was 0.8 mL/min and the injection volume was 10 μL. The detection was performed on a triple-quadruple tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization. Quantitative analysis was carried out at m/z 313.0 → 108.9 and m/z 472.6 → 436.2 for LNG and IS respectively. This method demonstrated the linearity of LNG over a concentration range of 0.5-50 ng/mL with a coefficient correlation (r) of 0.9973. The lower limit of quantification was 0.5 ng/mL. The intra- and inter-assay precisions were 2.9 and 11.2%, with an accuracy range from 94.8 to 108.4%. The stability data indicated that sample preparation and storage process had little effect on the concentration of LNG QC sample. The validated method was successfully applied to study the pharmacokinetics of LNG in beagle dog after vaginal administration of intravaginal ring.
建立了一种可用于测定比格犬血浆中左炔诺孕酮(LNG)浓度的特异性和灵敏的高效液相色谱 - 串联质谱法。具体而言,特非那定用作内标(IS)。在Kinetex - C 110A柱(内径3×30 mm,2.6μm,菲罗门公司)上实现分离,使用由甲醇(0.1%甲酸)和水(0.1%甲酸)组成的梯度流动相。流速为0.8 mL / min,进样量为10μL。通过电喷雾电离在三重四极杆串联质谱仪上采用多反应监测模式进行检测。分别对LNG和IS在m/z 313.0→108.9和m/z 472.6→436.2处进行定量分析。该方法证明LNG在0.5 - 50 ng/mL浓度范围内呈线性,相关系数(r)为0.9973。定量下限为0.5 ng/mL。批内和批间精密度分别为2.9%和11.2%,准确度范围为94.8%至108.4%。稳定性数据表明样品制备和储存过程对LNG质量控制样品的浓度影响很小。该验证方法成功应用于研究比格犬阴道给予阴道环后LNG的药代动力学。