Abstract

Using the device of an implant (Fig. 1) for direct stimulation of the eighth cranial nerve (Zwicker et al., 1986) measurements have been performed after implantation of one electrode in the nervus suralis of the first author. The results show that threshold of sensation is reached at voltage amplitudes of about 600 mV for sinusoidal stimuli almost frequency independent in the range between 100 Hz and 3 kHz (Fig. 2). The impedance of the electrode (Fig. 3) was found to be remarkably smaller compared with values measured by Zollner (1982) in Ringer's solution. No clear relation between threshold value or impedance and active electrode area could be detected. However, there was a clear dependence of the threshold voltage on the angle between the direction of puncture of the electrode and the direction of the nerve. Parallel puncturing resulted in a 13 dB less sensitive threshold in relation to perpendicular puncturing. The practical dynamic range between the threshold of sensation and the threshold of pain was found to be 10 to 12 dB.

摘要

使用一种植入装置(图1)直接刺激第八对脑神经(茨维克等人,1986年),在第一作者的腓肠神经植入一个电极后进行了测量。结果表明,对于正弦刺激,在100赫兹至3千赫兹范围内几乎与频率无关,在约600毫伏的电压幅度时达到感觉阈值(图2)。发现该电极的阻抗(图3)与佐尔纳(1982年)在林格氏液中测量的值相比明显更小。未检测到阈值或阻抗与有源电极面积之间的明确关系。然而,阈值电压明显依赖于电极穿刺方向与神经方向之间的夹角。与垂直穿刺相比,平行穿刺导致阈值灵敏度降低13分贝。发现感觉阈值和疼痛阈值之间的实际动态范围为10至12分贝。