Suppr超能文献

线性免疫测定:一种用于筛查有不良产科病史的产前患者TORCH复合物的快速检测方法。

Line Immunoassay: A Rapid Test for Screening TORCH Complex in Antenatal Patients with Bad Obstetric History.

作者信息

Kumar H, Singh V A, Isha M, Mehta S, Garg R, Shinu P

机构信息

Harit Kumar, Post-Graduate Student, Department of Microbiology, Maharishi Markandeshwar Institute of Medical Science & Research (MMIMSR), Maharishi Markandeshwar University(MMU), Mullana, Ambala, Haryana, India.

出版信息

Mymensingh Med J. 2018 Jul;27(3):641-644.

Abstract

TORCH {Toxoplasma gondii, Rubella, Cytomegalovirus (CMV), the Herpes Simplex Virus (HSV)} infection causes pregnancy wastage at any stage of gestation. Serological assays can be an important tool for diagnosis. It includes ELISA which is highly specific & sensitive with certain drawbacks like time consuming and for each genus separate test have to be done. Line-Immunoassay (LIA), a newer, cheaper and reliable technique on contrary is done on single panel strip. The present retrospective study was conducted with the aim to evaluate the efficacy of Line Immunoassay for detection of TORCH IgM antibodies. A total of 630 samples from the pregnant women with Bad Obstetric History (BOH) attending OPD and IPD of Obstetrics and Gynecology Department of Maharishi Markandeshwar Institute of Medical Science & Research (MMIMSR), Mullana, Ambala, Haryana, India from 2011 to 2015 were subjected to Line-Immunoassay and ELISA for detection of IgM antibodies against TORCH agents in Department of Microbiology. The analysis for TORCH complex showed 32.85% positivity by LIA while 36.03% by ELISA. The diagnostic accuracy of LIA when ELISA considered gold standard was also exhibited which showed Sensitivity of 90.75%, Specificity of 99.75% while PPV & NPV were 99.52%, 95.05% respectively. The statistical analysis showed results were statistically insignificant (p value >0.05). Comparison of detection of TORCH IgM antibodies by ELISA & Line-Immunoassay express good sensitivity & specificity requiring significantly less time and low cost by Line-Immunoassay, concludes that Line-Immunoassay may be used as screening test.

摘要

TORCH(弓形虫、风疹、巨细胞病毒(CMV)、单纯疱疹病毒(HSV))感染可在妊娠的任何阶段导致妊娠失败。血清学检测可能是诊断的重要工具。它包括酶联免疫吸附测定(ELISA),该方法具有高度特异性和敏感性,但存在一些缺点,如耗时,且针对每个属都必须进行单独检测。相反,线性免疫测定(LIA)是一种更新的、更便宜且可靠的技术,它在单个检测条上进行。本回顾性研究旨在评估线性免疫测定在检测TORCH IgM抗体方面的有效性。2011年至2015年期间,从印度哈里亚纳邦安巴拉穆拉纳市玛哈希·马尔坎德什瓦尔医学科学与研究学院(MMIMSR)妇产科门诊和住院部的有不良产科史(BOH)的孕妇中总共采集了630份样本,在微生物学系进行线性免疫测定和ELISA检测,以检测针对TORCH病原体的IgM抗体。TORCH复合物分析显示,线性免疫测定的阳性率为32.85%,而ELISA为36.03%。还展示了以ELISA为金标准时线性免疫测定的诊断准确性,其敏感性为90.75%,特异性为99.75%,阳性预测值和阴性预测值分别为99.52%、95.05%。统计分析表明结果无统计学意义(p值>0.05)。ELISA和线性免疫测定对TORCH IgM抗体检测的比较表明,线性免疫测定具有良好的敏感性和特异性,所需时间显著减少且成本较低,得出结论:线性免疫测定可作为筛查试验。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验