Suppr超能文献

脑肿瘤患者三维多通道磁共振波谱成像重建中线圈组合策略的比较

A comparison of coil combination strategies in 3D multi-channel MRSI reconstruction for patients with brain tumors.

作者信息

Vareth Maryam, Lupo Janine, Larson Peder, Nelson Sarah

机构信息

UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA.

Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.

出版信息

NMR Biomed. 2018 Nov;31(11):e3929. doi: 10.1002/nbm.3929. Epub 2018 Aug 31.

Abstract

The goal of this study was to find the most robust algorithm for a phase-sensitive coil combination of 3D single-cycle and lactate-edited, multi-channel H-1 point-resolved spectroscopy (PRESS) localized echo planar spectroscopic imaging (EPSI) data for clinical applications in the brain. Data were acquired over 5-10 minutes at 3T using 8- or 32-channel array coils. Peak referencing with residual water and N-acetyl-aspartate, first-point phasing, generalized least squared (GLS) and whitened singular-value decomposition (WSVD) combination algorithms were evaluated relative to unsuppressed water with data from a phantom, six volunteers and 55 patients with brain tumors. Comparison metrics were signal-to-noise ratio, coefficient of variance and percent signal increase. Where residual water was present, using it as a reference peak for phasing and weighting factors from an imaging calibration scan gave the best overall performance. Greater improvement was seen for large selected volumes (>720 cm ) and for the 32-channel array (25%) compared with the 8-channel array (19%). Applying voxel-by-voxel phase corrections produced a larger increase in performance for the 32- versus 8-channel coil. We conclude that, for clinically relevant 3D H-1 PRESS localized EPSI studies, the most robust technique employed individual phase maps generated from high residual water and individual amplitude maps generated from calibration scans.

摘要

本研究的目的是为用于脑部临床应用的三维单周期和乳酸编辑多通道氢-1点分辨光谱法(PRESS)定位回波平面光谱成像(EPSI)数据找到最稳健的相敏线圈组合算法。使用8通道或32通道阵列线圈在3T下采集5至10分钟的数据。相对于来自体模、6名志愿者和55名脑肿瘤患者的数据中的未抑制水,评估了使用残余水和N-乙酰天门冬氨酸进行峰值参考、首点相位校正、广义最小二乘法(GLS)和白化奇异值分解(WSVD)组合算法。比较指标为信噪比、变异系数和信号增加百分比。在存在残余水的情况下,将其用作成像校准扫描的相位参考峰和加权因子可获得最佳整体性能。与8通道阵列(19%)相比,对于大的选定体积(>720 cm³)和32通道阵列(25%),性能有更大提升。逐体素应用相位校正对32通道线圈与8通道线圈相比性能提升更大。我们得出结论,对于临床相关的三维氢-1 PRESS定位EPSI研究,最稳健的技术是采用由高残余水生成的个体相位图和由校准扫描生成的个体幅度图。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/02cc/6290901/21969f7ed7ee/nihms-995585-f0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验