Acad Radiol. 2019 Aug;26(8):e216-e223. doi: 10.1016/j.acra.2018.07.015. Epub 2018 Sep 8.
To explore the imaging features of whole uterus volume CT perfusion (vCTP) and the influence factors of blood supply in cervical squamous carcinoma (CSC).
vCTP was performed on a 640-slice computed tomography system in 43 patients with CSC diagnosed by biopsy, and 24 cases of them underwent magnetic resonance imaging. The size of the tumor was measured on vCTP and magnetic resonance (MR) images. Perfusion parameters, including arterial blood flow (AF), blood volume, and permeability surface (PS), were measured by two radiologists, using interclass correlation coefficient to evaluate the interobserver reliability. The difference of tumor size and perfusion data was analyzed by paired t test and rank sum test. The correlation of perfusion parameters with some factors was analyzed by Pearson or Spearman correlation analysis.
Tumor sizes were not significantly different between vCTP and MR images. The interclass correlation coefficient of each parameter was 0.818-0.945. The AF value of CSC was significantly higher than normal uterine body, and the blood volume and PS values of CSC were not statistically different compared with those of normal uterine body. There was no significant difference in AF value of CSC among different FIGO stages and pathological grades. The AF and PS values of CSC were negatively correlated with the age of the patients.
The vCTP could accurately shows the size of the CSC with use of MR as the reference standard, and its perfusion parameters have good measurement stability; the CSC was hypervascular, but this trend was less pronounced in older women.
探讨全子宫容积 CT 灌注(vCTP)成像特点及宫颈鳞癌(CSC)的血供影响因素。
对 43 例经活检证实的 CSC 患者行 640 层 CT vCTP 扫描,其中 24 例行磁共振(MR)检查。在 vCTP 及 MR 图像上测量肿瘤大小。由 2 位放射科医师分别测量灌注参数,包括动脉血流量(AF)、血容量(BV)及通透性表面(PS),采用组内相关系数评估观察者间的可靠性。采用配对 t 检验和秩和检验分析肿瘤大小和灌注数据的差异,采用 Pearson 或 Spearman 相关分析分析灌注参数与某些因素的相关性。
vCTP 与 MR 图像上肿瘤大小无显著差异。各参数的组内相关系数为 0.818-0.945。CSC 的 AF 值明显高于正常子宫体,BV 值和 PS 值与正常子宫体比较,差异无统计学意义。不同 FIGO 分期和病理分级的 CSC 间 AF 值差异无统计学意义。CSC 的 AF 值和 PS 值与患者年龄呈负相关。
以 MR 为参考标准,vCTP 能准确显示 CSC 的大小,其灌注参数具有良好的测量稳定性;CSC 为富血供肿瘤,但在老年女性中这种趋势不明显。