Suppr超能文献

一种使用THUNDERBEAT设备进行无接触隐静脉移植的新型采集技术。

A novel harvesting technique for a no-touch saphenous vein graft using the THUNDERBEAT device.

作者信息

Ishizawa Ai, Hamasaki Azumi, Uchida Tetsuro, Sadahiro Mitsuaki

机构信息

Second Department of Surgery, Yamagata University Faculty of Medicine 2-2-2 Iida-Nishi, Yamagata, 990-9585, Japan.

Second Department of Surgery, Yamagata University Faculty of Medicine, Yamagata, Japan.

出版信息

Multimed Man Cardiothorac Surg. 2018 Sep 17;2018. doi: 10.1510/mmcts.2018.051.

Abstract

The no-touch technique of saphenous vein harvesting involves harvesting the vein as a pedicled graft, together with its surrounding adipose tissue, while avoiding direct contact and excessive high-pressure expansion. This technique offers the possibility of comparable long-term graft patency to that of an internal mammary artery graft. However, the wound complications using the no-touch technique can be more significant than those using a conventional skeletonized technique. To solve the problem of leg wound trouble and to perform the no-touch saphenous vein harvesting more rapidly and efficiently, we have developed a new harvesting technique using a novel energy device, the THUNDERBEAT. This harvesting technique offers quicker tissue dissection, safer sealing of branch vessels, and fewer wound complications, without the risk of thermal damage to the graft.

摘要

大隐静脉获取的非接触技术是将静脉作为带蒂移植物连同其周围脂肪组织一起获取,同时避免直接接触和过度高压扩张。该技术提供了与乳内动脉移植物相当的长期移植物通畅率的可能性。然而,使用非接触技术的伤口并发症可能比使用传统骨骼化技术的更严重。为了解决腿部伤口问题并更快速有效地进行非接触大隐静脉获取,我们开发了一种使用新型能量设备THUNDERBEAT的新获取技术。这种获取技术能更快地进行组织解剖,更安全地封闭分支血管,且伤口并发症更少,同时不存在移植物热损伤风险。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验