Abstract

The HEARTSTRING III Proximal Seal System is a useful proximal anastomosis assist device, but it has a notable drawback in that the removal process is irreversible. If thread cutting occurs during the tying process, repair without side clamping is difficult. We have developed a simple modified technique for the safer removal of the HEARTSTRING device and we demonstrate it in this video tutorial.

摘要

HEARTSTRING III近端封闭系统是一种有用的近端吻合辅助装置,但它有一个显著缺点,即移除过程是不可逆的。如果在打结过程中发生缝线切割,不进行侧方钳夹的修复很困难。我们开发了一种简单的改良技术,用于更安全地移除HEARTSTRING装置,并在本视频教程中进行演示。