Suppr超能文献

预期根骨位置设置方法评估正畸治疗中根骨位置的准确性和可靠性。

Accuracy and reliability of the expected root position setup methodology to evaluate root position during orthodontic treatment.

机构信息

Division of Orthodontics, University of California at San Francisco, San Francisco, Calif.

School of Dentistry, University of California at San Francisco, San Francisco, Calif.

出版信息

Am J Orthod Dentofacial Orthop. 2018 Oct;154(4):583-595. doi: 10.1016/j.ajodo.2018.05.010.

Abstract

INTRODUCTION

Current methods to evaluate root position either are inaccurate (panoramic radiograph) or expose patients to relatively large amounts of radiation (cone-beam computed tomography [CBCT]). A method to evaluate root position by generating an expected root position (ERP) setup was recently reported but has not been validated. The purpose of this study was to quantitatively assess the accuracy and reliability of the ERP setup with adequate statistical power.

METHODS

This retrospective study included 15 subjects who had completed phase 2 orthodontic treatment. An ERP setup was generated for all patients after treatment. The ERP setup was compared with the posttreatment CBCT scan, which served as the control. The mesiodistal angulation and buccolingual inclination of all teeth in both the ERP setup and the posttreatment CBCT scan were measured and compared. Bland-Altman analysis was used to assess interoperator reliability, intraoperator reliability, and agreement between the ERP setup and the posttreatment CBCT scan.

RESULTS

Bland-Altman plots showed high interoperator and intraoperator reliabilities. These plots also showed strong agreement between the ERP setup and the posttreatment CBCT scan; 11.8% of teeth measured for mesiodistal angulation and 9.6% of teeth measured for buccolingual inclination were outside the ±2.5° range of clinical acceptability.

CONCLUSIONS

We validated that the method to generate an ERP setup to evaluate root position for posttreatment orthodontic assessment is accurate and reliable.

摘要

简介

目前评估牙根位置的方法要么不准确(全景片),要么使患者暴露在相对较大的辐射量下(锥形束 CT [CBCT])。最近报道了一种通过生成预期牙根位置(ERP)设置来评估牙根位置的方法,但尚未得到验证。本研究的目的是使用足够的统计能力定量评估 ERP 设置的准确性和可靠性。

方法

本回顾性研究纳入了 15 名已完成二期正畸治疗的患者。为所有患者生成 ERP 设置。将 ERP 设置与治疗后的 CBCT 扫描进行比较,后者作为对照。测量并比较 ERP 设置和治疗后 CBCT 扫描中所有牙齿的近远中向角度和颊舌向倾斜度。Bland-Altman 分析用于评估操作者间可靠性、操作者内可靠性以及 ERP 设置与治疗后 CBCT 扫描之间的一致性。

结果

Bland-Altman 图显示出操作者间和操作者内的高度可靠性。这些图还显示出 ERP 设置与治疗后 CBCT 扫描之间具有很强的一致性;对于近远中向角度的测量,有 11.8%的牙齿和对于颊舌向倾斜度的测量,有 9.6%的牙齿超出了临床可接受的±2.5°范围。

结论

我们验证了生成 ERP 设置来评估正畸治疗后牙根位置的方法是准确和可靠的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验