Abstract

OBJECTIVE

To compare the three-dimensional (3D) linear displacements and the mesiodistal and buccolingual angulation changes after orthodontic treatment in digital dental models (DDMs) and 3D models derived from cone-beam computed tomography (CBCT).

SETTINGS AND SAMPLE POPULATION

Digital dental model and CBCT scans were selected from 24 adults who had undergone orthodontic treatment for mandibular anterior crowding.

MATERIAL AND METHODS

3D linear displacements and changes in angular measurements (mesiodistal and buccolingual angulation) were assessed in pre- and post-treatment DDM and CBCT images using the software ITK-snap and 3D SlicerCMF. Intra- and inter-rater agreement of measurements in DDM and CBCT were tested using the intraclass correlation coefficient (ICC). DDM and CBCT measurements were compared using the Wilcoxon test (P < .05), ICC and Bland-Altman plots.

RESULTS

Intra- and inter-rater agreement varied from good (ICC > 0.75) to excellent (ICC > 0.90) for both DDM and CBCT measurements. Although no significant difference between DDM and CBCT methods was observed for linear measurements of tooth movement, the angular assessments were different for most measurements. The agreement between measurements from both assessments varied from poor to excellent.

CONCLUSIONS

Longitudinal assessments of tooth movements including 3D linear displacements and mesiodistal and buccolingual angulation are reproducible when using both DDM and CBCT. Changes in angular measurements due to orthodontic treatment are discordant when measured in the digital models (clinical crown) and in the CBCT images (whole tooth).

摘要

目的

比较数字化牙模(DDM)和锥形束 CT(CBCT)三维模型中正畸治疗后的三维(3D)线性位移及近远中向和颊舌向倾斜角度的变化。

设置和样本人群

从 24 名接受下颌前牙拥挤正畸治疗的成年人中选择数字化牙模和 CBCT 扫描。

材料和方法

使用 ITK-snap 和 3D SlicerCMF 软件,在治疗前后的 DDM 和 CBCT 图像中评估 3D 线性位移和角度测量(近远中向和颊舌向倾斜角度)的变化。使用组内相关系数(ICC)检验 DDM 和 CBCT 测量的内部和内部一致性。使用 Wilcoxon 检验(P<.05)、ICC 和 Bland-Altman 图比较 DDM 和 CBCT 的测量值。

结果

DDM 和 CBCT 测量的内部和内部一致性均较好(ICC>.75)到极好(ICC>.90)。虽然 DDM 和 CBCT 方法在牙齿移动的线性测量方面没有显著差异,但大多数测量的角度评估结果不同。两种评估方法之间的测量值一致性从较差到极好不等。

结论

使用 DDM 和 CBCT 均可重复进行牙齿运动的纵向评估,包括 3D 线性位移和近远中向和颊舌向倾斜角度。正畸治疗引起的角度测量变化在数字化模型(临床牙冠)和 CBCT 图像(整个牙齿)中测量时存在差异。

相似文献

1
Comparison of linear and angular changes assessed in digital dental models and cone-beam computed tomography.
Orthod Craniofac Res. 2020 Feb;23(1):118-128. doi: 10.1111/ocr.12352. Epub 2019 Nov 14.
2
Dental long axes using digital dental models compared to cone-beam computed tomography.
Orthod Craniofac Res. 2022 Feb;25(1):64-72. doi: 10.1111/ocr.12489. Epub 2021 May 24.

引用本文的文献

本文引用的文献

1
Accuracy and reliability of mandibular digital model registration with use of the mucogingival junction as the reference.
Oral Surg Oral Med Oral Pathol Oral Radiol. 2019 Apr;127(4):351-360. doi: 10.1016/j.oooo.2018.10.003. Epub 2018 Oct 16.
3
Accuracy and reliability of the expected root position setup methodology to evaluate root position during orthodontic treatment.
Am J Orthod Dentofacial Orthop. 2018 Oct;154(4):583-595. doi: 10.1016/j.ajodo.2018.05.010.
7
Torque differences according to tooth morphology and bracket placement: a finite element study.
Eur J Orthod. 2017 Aug 1;39(4):411-418. doi: 10.1093/ejo/cjw074.
8
3D Mandibular Superimposition: Comparison of Regions of Reference for Voxel-Based Registration.
PLoS One. 2016 Jun 23;11(6):e0157625. doi: 10.1371/journal.pone.0157625. eCollection 2016.
9
A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.
J Chiropr Med. 2016 Jun;15(2):155-63. doi: 10.1016/j.jcm.2016.02.012. Epub 2016 Mar 31.
10
Comparison and reproducibility of 2 regions of reference for maxillary regional registration with cone-beam computed tomography.
Am J Orthod Dentofacial Orthop. 2016 Apr;149(4):533-42. doi: 10.1016/j.ajodo.2015.09.026.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验