三种热处理镍钛旋转锉系统在弯曲根管中塑形能力的显微计算机断层扫描评估

A microcomputed tomography evaluation of the shaping ability of three thermally-treated nickel-titanium rotary file systems in curved canals.

作者信息

Huang Zhuwei, Quan Jingjing, Liu Jia, Zhang Wen, Zhang Xiaolei, Hu Xiaoli

机构信息

Department of Operative Dentistry and Endodontics, Guanghua School of Stomatology, Affiliated Stomatological Hospital, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong Province, China.

出版信息

J Int Med Res. 2019 Jan;47(1):325-334. doi: 10.1177/0300060518801451. Epub 2018 Oct 3.

Abstract

OBJECTIVE

To evaluate the shaping ability of three thermally-treated rotary nickel-titanium (NiTi) systems including ProTaper Next (PTN), HyFlex™ CM (HFCM) and HyFlex™ EDM (HFEDM) during root canal preparation in simulated root canals.

METHODS

A total of 45 simulated root canals were divided into three groups ( n = 15) and prepared with PTN, HFCM or HFEDM files up to size 25. Microcomputed tomography (microCT) was used to scan the specimens before and after instrumentation. Volume and diameter changes, transportations and centring ratios at 11 levels of the simulated root canals were measured and compared.

RESULTS

HFEDM caused significantly greater volume increases than HFCM and PTN in the entire root canal and in the apical and middle thirds. HFCM removed the least amount of resin in the coronal third compared with HFEDM and PTN. Overall, HFCM caused significantly less transportation in the apical 2 mm and was better centred than PTN in the apical 3 mm.

CONCLUSION

Under the conditions of this study, all systems prepared curved canals without significant shaping errors and instrument fracture. PTN and HFCM cut less resin than HFEDM. HFCM stayed centred apically and cut the least material coronally.

摘要

目的

评估三种经过热处理的旋转镍钛(NiTi)系统,即ProTaper Next(PTN)、HyFlex™ CM(HFCM)和HyFlex™ EDM(HFEDM)在模拟根管预备过程中的根管塑形能力。

方法

将45个模拟根管分为三组(n = 15),分别用PTN、HFCM或HFEDM锉预备至25号。在器械预备前后,使用微型计算机断层扫描(microCT)对标本进行扫描。测量并比较模拟根管11个水平处的体积和直径变化、偏移情况及定心率。

结果

在整个根管以及根尖和中三分之一区域,HFEDM导致的体积增加显著大于HFCM和PTN。与HFEDM和PTN相比,HFCM在冠三分之一区域去除的树脂量最少。总体而言,HFCM在根尖2 mm处导致的偏移显著更少,且在根尖3 mm处比PTN定心更好。

结论

在本研究条件下,所有系统在预备弯曲根管时均未出现明显的塑形误差和器械折断。PTN和HFCM去除的树脂比HFEDM少。HFCM在根尖处保持居中,在冠部去除的材料最少。