Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.
Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.
J Endod. 2018 Jan;44(1):115-119. doi: 10.1016/j.joen.2017.05.023. Epub 2017 Oct 9.
The aims of the present study were to examine the surface topographies of intact HyFlex CM and HyFlex EDM nickel-titanium files and to compare alterations in the surface topographies of these files after root canal preparation of severely curved canals of molar teeth.
Eight HyFlex CM (25/.08) and 8 HyFlex EDM (25/.08) files were included in the present study. In total, 64 severely curved canals of molar teeth, with curvature angles ranging between 50° and 70°, were prepared with HyFlex CM and EDM (n = 32 in each group). Quantitative and qualitative analyses of the files' surface deformation were performed by using three-dimensional optical profilometry before and after root canal preparation. The data were analyzed with the Student t test at the 5% significant level by using SPSS 21.0 software.
In the HyFlex EDM group, the qualitative evaluation revealed the presence of cracks and microcavities after use of the file for root canal preparation, whereas only minor surface deformation was observed in the HyFlex CM group. The average roughness, root mean square roughness, and peak to valley height values of the HyFlex EDM group were significantly higher than those of the HyFlex CM group before and after root canal preparation (P < .05). The surface roughness values were statistically significantly increased in the HyFlex CM group after root canal preparation (P < .05). In contrast, the increase in the HyFlex EDM group was not statistically significant (P > .5).
Within the limitations of the present study, the HyFlex CM files showed significantly higher surface alterations compared with the HyFlex EDM files after the preparation of severely curved root canals.
本研究的目的是观察 HyFlex CM 和 HyFlex EDM 镍钛锉在未经使用和使用后的表面形貌,并比较这两种锉在预备磨牙重度弯曲根管后表面形貌的变化。
本研究纳入了 8 根 HyFlex CM(25/.08)和 8 根 HyFlex EDM(25/.08)锉。共预备了 64 个重度弯曲的磨牙根管,其弯曲角度在 50°到 70°之间,用 HyFlex CM 和 EDM (每组 n = 32)预备。在根管预备前后,使用三维光学轮廓仪对锉的表面变形进行定量和定性分析。使用 SPSS 21.0 软件,采用 Student t 检验对数据进行分析,检验水准为 5%。
在 HyFlex EDM 组中,锉在根管预备后出现了裂纹和微孔,而在 HyFlex CM 组中仅观察到轻微的表面变形。在根管预备前后,HyFlex EDM 组的平均粗糙度、均方根粗糙度和峰谷高度值均显著高于 HyFlex CM 组(P <.05)。根管预备后,HyFlex CM 组的表面粗糙度值显著增加(P <.05)。相比之下,HyFlex EDM 组的增加并不显著(P >.5)。
在本研究的限制范围内,与 HyFlex EDM 锉相比,HyFlex CM 锉在预备重度弯曲根管后表现出更高的表面变化。