Solomon S B, Peggie J R, Grealy G, Leach V A
Health Phys. 1987 Feb;52(2):143-8. doi: 10.1097/00004032-198702000-00002.
An integrating Rn daughter dosimeter using conventional Dy-doped CaSO4 thermoluminescent (TL) material has been developed for use as a personal monitor. The dosimeter was found to have a linear response over the range 0.5 WL-h to 25 WL-h and to be insensitive to the state of equilibrium of the Rn daughters. The use of the dosimeter to monitor both 222Rn and 220Rn daughters is described. The limiting sensitivity of the dosimeter, at a sampling rate of 1 L min-1, was determined to be 0.1 WL-h for 222Rn daughters and 0.5 WL-h for 220Rn daughters. The application of the thermoluminescent dosimeter (TLD) to occupational monitoring of 222Rn and 220Rn daughters is discussed.
一种使用传统掺杂镝的硫酸钙热释光(TL)材料的集成氡子体剂量计已被开发用作个人监测器。该剂量计在0.5 WL-h至25 WL-h范围内具有线性响应,并且对氡子体的平衡状态不敏感。描述了该剂量计用于监测222Rn和220Rn子体的情况。在采样率为1 L min-1时,该剂量计对222Rn子体的极限灵敏度确定为0.1 WL-h,对220Rn子体为0.5 WL-h。讨论了热释光剂量计(TLD)在222Rn和220Rn子体职业监测中的应用。