Industrial radiotracer application in flow rate measurement and flowmeter calibration using Tc and Au nanoparticles radioisotope.

作者信息

Mohd Yunos Mohd Amirul Syafiq, Hussain Siti Aslina, Sipaun Susan Maria

机构信息

Faculty of Engineering, Universiti Putra Malaysia UPM, 43400 Serdang, Selangor, Malaysia; Plant Assessment Technology Group, Malaysian Nuclear Agency, 43000 Kajang, Malaysia.

Faculty of Engineering, Universiti Putra Malaysia UPM, 43400 Serdang, Selangor, Malaysia.

出版信息

Appl Radiat Isot. 2019 Jan;143:24-28. doi: 10.1016/j.apradiso.2018.10.008. Epub 2018 Oct 12.

Abstract

The flow rate or fluid velocity measurement is important to maintain fluid flow quality performance in the systems. This study focuses on determination of volumetric flow rate measurement and to calibrate the conventional flowmeter using industrial radiotracer approach in quadrilateral gas-liquid bubble column reactor. In this work, two different radioisotopes which emit γ-ray have been chosen as radioactive tracer which is Tc produced from Mo/Tc radioisotope generator and Au nanoparticle form neutron activation at research nuclear reactor TRIGA Mark II. Both radioisotopes representing liquid and solid tracer purposely designed for tracing liquid flow. The peak to peak radiotracer method known as pulse velocity method was applied to determine the volumetric flow rate. The radiation signals were monitored using 4 unit NaI scintillation detectors located at 4 different points nearby the inlet and outlet of the quadrilateral bubble column reactor process stream. The water volume inside the bubble column reactor was fixed at 0.04 m and liquid flow rates in this reactor were specified on installed flowmeter at different reference value which is 4 lpm, 8 lpm, and 12 lpm, respectively. The experimental result shows very good linearity and repeatability by following the theoretical equations with less uncertainty in volumetric flow rate measurement. The obtained results also validated the effectiveness of the proposed method for the installed flowmeter calibration efficiency.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验