Suppr超能文献

马近端指骨完全单关节矢状旁骨折线性与三角形螺钉构型体外稳定效果比较

In vitro comparison of linear vs triangular screw configuration to stabilize complete uniarticular parasagittal fractures of the proximal phalanx in horses.

作者信息

Labens Raphael, Khairuddin Nurul H, Murray Mark, Jermyn Kieri, Ahmad Roohi S

机构信息

School of Animal and Veterinary Sciences, Faculty of Science, Charles Sturt University, Wagga Wagga, New South Wales, Australia.

Department of Farm and Exotic Animal Medicine and Surgery, Faculty of Veterinary Medicine, Universiti Putra Malaysia, Selangor, Malaysia.

出版信息

Vet Surg. 2019 Jan;48(1):96-104. doi: 10.1111/vsu.13123. Epub 2018 Nov 7.

Abstract

OBJECTIVE

To assess fracture gap reduction and stability of linear vs triangular 4.5-mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures.

STUDY DESIGN

Experimental.

SAMPLE POPULATION

Fourteen equine cadaver limbs/horses.

METHODS

Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.

RESULTS

Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (P  = .008). Triangular repairs reduced fractures better irrespective of loading (P  = .003; P  < .001). The type of repair was not correlated with fracture gap grades at unloaded mid and loaded dorsal P1 sites.

CONCLUSION

Repair of uniarticular complete parasagittal fractures with a triangular screw configuration improved in vitro fracture gap reduction and stability.

CLINICAL SIGNIFICANCE

Triangular lag screw repair likely improves biomechanical conditions during postoperative weight bearing.

摘要

目的

评估在实验性单关节完全性前肢近端指骨(P1)骨折中,使用4.5毫米线性拉力螺钉与三角形拉力螺钉修复时骨折间隙的减小情况及稳定性。

研究设计

实验性研究。

样本群体

14个马的尸体肢体/马匹。

方法

在4牛米的插入扭矩下用2枚拉力螺钉修复模拟骨折(线性修复)。在腿部卸载及加载行走时产生的力的情况下进行计算机断层扫描(CT)成像。在CT扫描前,将骨折修复方式改为使用相同插入扭矩放置3枚拉力螺钉(三角形修复)。由2名观察者对骨折间隙宽度进行定性评估,并根据相对于P1背侧、中部和掌侧平均体素大小的间隙测量值进行分级。使用Cohen's κ评估观察者间的一致性。通过使用Kendall's τ-b相关系数和配对非参数检验,评估修复类型、加载条件和测量部位对骨折间隙分级的影响。显著性设定为P≤0.05。

结果

在三角形修复中,加载与骨折间隙增宽之间的一致性一般(κ = 0.53),而在线性修复中一致性良好(κ = 0.81)。加载导致线性修复中的骨折间隙增宽(P = 0.008)。无论加载情况如何,三角形修复能更好地减小骨折间隙(P = 0.003;P < 0.001)。修复类型与卸载中部和加载背侧P1部位的骨折间隙分级无关。

结论

采用三角形螺钉构型修复单关节完全矢状旁骨折可改善体外骨折间隙的减小及稳定性。

临床意义

三角形拉力螺钉修复可能改善术后负重期间的生物力学状况。