Preconcentrations of Cu(II), Ni(II) and Pb(II) ions by using Coprinus silvaticus immobilized multiwalled carbon nanotube (MWCNT) were investigated. Effects of important parameters on preconcentration procedure were examined. The best pH values of for Cu(II), Ni(II) and Pb(II) were found to be 6.0, 6.0 and 4.0, respectively. Flow rate of sample solution was 2.0 mL min, while desorption was achieved at 1.0 mL min flow rate. Preconcentration factors were achieved as 60 for Cu(II), Ni(II) and 70 for Pb(II) (by dividing initial sample volume to final volume). LODs were calculated as 0.014, 0.016 and 0.093 ng mL, respectively for Cu(II), Ni(II) and Pb(II). Accuracy of the method was checked by applying to certified reference samples. Inductively coupled plasma optical emission spectrometer (ICP OES) was employed for measurements of Cu(II), Ni(II) and Pb(II) in digested baby food samples.
采用固定化于多壁碳纳米管(MWCNT)上的草菇(Coprinus silvaticus)对 Cu(II)、Ni(II) 和 Pb(II) 离子进行预浓缩。考察了重要参数对预浓缩过程的影响。发现 Cu(II)、Ni(II) 和 Pb(II) 的最佳 pH 值分别为 6.0、6.0 和 4.0。样品溶液的流速为 2.0 mL/min,而洗脱流速为 1.0 mL/min。Cu(II)、Ni(II) 和 Pb(II) 的预浓缩因子分别为 60、60 和 70(通过将初始样品体积除以最终体积得到)。Cu(II)、Ni(II) 和 Pb(II) 的检出限分别计算为 0.014、0.016 和 0.093 ng/mL。通过应用于认证参考样品来检查该方法的准确性。电感耦合等离子体光学发射光谱仪(ICP OES)用于测量婴儿食品样品消解液中的 Cu(II)、Ni(II) 和 Pb(II)。