文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

共同心房及相关畸形:低剂量双源计算机断层扫描评估

Common atrium and the associated malformations: Evaluation by low-dose dual-source computed tomography.

作者信息

Zhang Yi, Yang Zhi-Gang, Yang Meng-Xi, Shi Ke, Li Rui, Diao Kai-Yue, Guo Ying-Kun

机构信息

Department of Radiology, National Key Laboratory of Biotherapy, West China Hospital.

Department of Radiology.

出版信息

Medicine (Baltimore). 2018 Nov;97(46):e12983. doi: 10.1097/MD.0000000000012983.


DOI:10.1097/MD.0000000000012983
PMID:30431572
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC6257481/
Abstract

Common atrium (CA) is a rare complex congenital heart disease. The studies of CA are mostly case reports, while few have been done regarding its morphological characteristics. We aimed to determine CA characteristics and diagnostic accuracy in assessing associated malformations in these patients with low-dose dual-source computed tomography (DSCT).Twenty-one pediatric and adolescent CA patients underwent low-dose DSCT. Different ventricular types and associated malformations were assessed. The diagnostic accuracy of DSCT and transthoracic echocardiography (TTE) in evaluating associated malformations were assessed. The effective doses of DSCT were calculated.Patients (n = 21) were divided into CA with biventricular physiology (n = 7) and CA with single ventricle (SV) (n = 14). There were 3 types of SV morphology: single left ventricle (n = 5), single right ventricle (n = 6), and undifferentiated ventricle (n = 3). In all, 22 associated malformations were seen in CA and 56 in CA with SV. DSCT was superior to TTE for detecting intracardiac anomalies (sensitivity: DSCT, 92.31% vs TTE, 76.92%), great vessels anomalies (sensitivity: DSCT, 100.00% vs TTE, 77.50%), and of collateral vessels (sensitivity: DSCT, 100% vs TTE, 20.00%). The estimated mean effective dose was 0.95 ± 0.44 mSv (<1 mSv).This study indicated that low-dose DSCT is an ideal alternative for pediatric and adolescent patients with CA, providing morphological details of CA and associated malformations with high accuracy.

摘要

共同心房(CA)是一种罕见的复杂先天性心脏病。关于CA的研究大多为病例报告,而对其形态特征的研究较少。我们旨在通过低剂量双源计算机断层扫描(DSCT)确定这些患者的CA特征及其在评估相关畸形方面的诊断准确性。

21例儿童和青少年CA患者接受了低剂量DSCT检查。评估了不同的心室类型和相关畸形。评估了DSCT和经胸超声心动图(TTE)在评估相关畸形方面的诊断准确性。计算了DSCT的有效剂量。

患者(n = 21)分为具有双心室生理功能的CA(n = 7)和单心室(SV)的CA(n = 14)。SV形态有3种类型:单左心室(n = 5)、单右心室(n = 6)和未分化心室(n = 3)。CA中总共发现22种相关畸形,CA合并SV中发现56种。在检测心内异常(敏感性:DSCT为92.31%,TTE为76.92%)、大血管异常(敏感性:DSCT为100.00%,TTE为77.50%)和侧支血管(敏感性:DSCT为100%,TTE为20.00%)方面,DSCT优于TTE。估计平均有效剂量为0.95±0.44 mSv(<1 mSv)。

本研究表明,低剂量DSCT是儿童和青少年CA患者的理想替代检查方法,能提供CA及其相关畸形的形态学细节,且准确性高。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0c96/6257481/0ee22138c614/medi-97-e12983-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0c96/6257481/84d4561814be/medi-97-e12983-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0c96/6257481/b20bf06071a5/medi-97-e12983-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0c96/6257481/0ee22138c614/medi-97-e12983-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0c96/6257481/84d4561814be/medi-97-e12983-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0c96/6257481/b20bf06071a5/medi-97-e12983-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0c96/6257481/0ee22138c614/medi-97-e12983-g003.jpg

相似文献

[1]
Common atrium and the associated malformations: Evaluation by low-dose dual-source computed tomography.

Medicine (Baltimore). 2018-11

[2]
Assessment of Double Outlet Right Ventricle Associated with Multiple Malformations in Pediatric Patients Using Retrospective ECG-Gated Dual-Source Computed Tomography.

PLoS One. 2015-6-26

[3]
Assessment of transposition of the great arteries associated with multiple malformations using dual-source computed tomography.

PLoS One. 2017-11-20

[4]
Assessment of tetralogy of Fallot-associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography.

BMC Cardiovasc Disord. 2017-12-4

[5]
Dual-source Computed Tomography for Evaluating Pulmonary Artery and Aorta in Pediatric Patients with Single Ventricle.

Sci Rep. 2017-10-17

[6]
Preoperative evaluation of anomalous pulmonary venous connection using dual-source computed tomography: Comparison with echocardiography.

Eur J Radiol. 2017-6-21

[7]
Accuracy, image quality, and radiation dose of prospectively ECG-triggered high-pitch dual-source CT angiography in infants and children with complex coarctation of the aorta.

Acad Radiol. 2014-10

[8]
Assessment of intracardiac and extracardiac anomalies associated with coarctation of aorta and interrupted aortic arch using dual-source computed tomography.

Sci Rep. 2019-8-12

[9]
Application of prospective ECG-gated high-pitch 128-slice dual-source CT angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children.

PLoS One. 2014-12-29

[10]
Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease.

Acta Radiol. 2012-4-1

引用本文的文献

[1]
Situs Inversus Partialis With a Wandering Spleen Having a Single Atrium: A Rare Tale of Survival.

Cureus. 2023-7-14

[2]
A 78-year-old man diagnosed with single atrium as congenital heart disease.

SAGE Open Med Case Rep. 2023-7-29

本文引用的文献

[1]
Preoperative evaluation of coronary artery fistula using dual-source computed tomography.

Int J Cardiol. 2017-2-1

[2]
Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose.

Eur J Radiol. 2016-12

[3]
Well-Tolerated and Undiscovered Common Atrium until Late Adulthood.

J Cardiovasc Ultrasound. 2016-9

[4]
Morphologic and functional abnormalities in patients with Ebstein's anomaly with cardiac magnetic resonance imaging: Correlation with tricuspid regurgitation.

Eur J Radiol. 2016-9

[5]
Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT.

Eur Radiol. 2017-2

[6]
Dual-source computed tomography for evaluating pulmonary artery in pediatric patients with cyanotic congenital heart disease: Comparison with transthoracic echocardiography.

Eur J Radiol. 2016-1

[7]
The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations.

Eur Radiol. 2016-8

[8]
Cardiac Computed Tomography versus Echocardiography in the Assessment of Stenotic Rheumatic Mitral Valve.

Echocardiography. 2016-3

[9]
Application of prospective ECG-gated high-pitch 128-slice dual-source CT angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children.

PLoS One. 2014-12-29

[10]
Accuracy, image quality, and radiation dose of prospectively ECG-triggered high-pitch dual-source CT angiography in infants and children with complex coarctation of the aorta.

Acad Radiol. 2014-10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索