Suppr超能文献

[中国汉族人与美国白种人眼前节结构的差异]

[Differences in anterior segment structure between Chinese Han people and American Caucasians].

作者信息

He N, Wu L L, Qi M, Lin S, Xin W

机构信息

Department of Ophthalmology, Peking University Third Hospital, Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing 100191, China.

出版信息

Zhonghua Yan Ke Za Zhi. 2018 Nov 11;54(11):820-826. doi: 10.3760/cma.j.issn.0412-4081.2018.11.005.

Abstract

To compare the difference of anterior segment structure between Chinese Han people and American Caucasians, and to explore the confounding factors of anterior chamber angle. Cross-sectional study. The study was designed to include two healthy groups of Chinese Han people (enrolled from Department of Ophthalmology, Peking University Third Hospital) and American Caucasians (enrolled from Department of Ophthalmology, University of California, San Francisco) from May 2008 to December 2010, each with approximately 120 participants, including 15 persons of each gender in each decade between 40 and 80 years of age. The parameters of the anterior segment were measured by the automatic refractive test, A-ultrasound and ultrasound biomicroscopy. Differences between the two groups were compared with the independent-sample test or Wilcoxon two-sample test for continuous variable data and the χ(2) test for classified variable data. Multiple linear regression models were performed to analyze the associated factors of anterior chamber angle. There were 118 subjects (118 eyes) and 117 subjects (117 eyes) enrolled in the Chinese and American Caucasians groups, respectively. Compared to Caucasians, Chinese had smaller A-ultrasound measured anterior chamber depth [(3.03±0.34) mm . (3.38±0.36) mm, -5.791, 0.001], smaller relative lens position [0.227 (0.198, 0.256) . 0.235 (0.191, 0.262), -3.063, =0.002], smaller axial length [23.3 (20.9,28.3) mm . 24.2 (20.8,28.5) mm, -5.510, 0.001], smaller iris root distance [0.111 (0.000, 0.401) mm . 0.142 (0.000, 0.451) mm, -3.188, 0.001], smaller ciliary body thickness at 1 mm posterior to the scleral spur [0.661 (0.424, 0.892) mm . 0.716 (0.467, 0.942) mm, -3.456, 0.001], smaller trabecular ciliary process distance [0.780 (0.410, 1.400) mm . 0.930 (0.420, 1.470) mm, -3.191, 0.001], smaller trabecular ciliary process angle [73.4° (36.3°, 115.3°) . 81.1° (47.9°, 147.9°), -3.407, =0.001], smaller angle opening distance at 500 μm (AOD500) [0.181 (0.000, 0.703) mm . 0.264 (0.000, 0.806) mm, -3.444, 0.001], smaller angle recess area (ARA) [0.118 (0.011, 0.457) mm(2) . 0.179 (0.000, 0.626) mm(2), -3.814, 0.001], larger spherical equivalent [0.40 (-5.80, 4.00) D . -0.70 (-8.00, 4.00) D, -5.454, 0.001], larger lens thickness [(4.62±0.40) mm (4.52±0.40) mm, 2.077, 0.039] and larger iris thickness [0.430 (0.280, 0.600) mm . 0.410 (0.240, 0.580) mm, -2.263, 0.024]. On average, with each decade of the increased age, Chinese had a greater decrease in the AOD500 than Caucasians (0.040 mm in Chinese . 0.030 mm in Caucasians), while the angle recess area decreased at the same rate (0.020 mm(2) in both groups). After adjusted for age, gender, spherical equivalent, axial length and other parameters of the anterior segment, the trabecular ciliary process angle [for AOD500, standardized regression coefficient (SRC)=0.487, (2)=0.549, 0.001; for ARA, SRC=0.372, (2)=0.502, 0.001] and anterior chamber depth (for AOD500, SRC=0.413, (2)=0.476, 0.001; for ARA, SRC=0.331, (2)=0.403, 0.001) were the main factors of anterior chamber angle parameters for Chinese and Caucasians, respectively. Compared with age and gender matched American Caucasians, Chinese Han people have more crowded anterior chambers and narrower anterior chamber angles. The more anteriorly positioned ciliary processes and shallower anterior chambers are the main factors that contributed to more crowded anterior chambers in Chinese Han people and American Caucasians, respectively. -.

摘要

比较中国汉族人与美国白种人眼前节结构的差异,并探讨前房角的混杂因素。横断面研究。本研究旨在纳入两组健康人群,一组为中国汉族人(来自北京大学第三医院眼科),另一组为美国白种人(来自美国加利福尼亚大学旧金山分校眼科),研究时间为2008年5月至2010年12月,每组约120名参与者,包括40至80岁各年龄段中每个性别15人。采用自动验光、A超和超声生物显微镜测量眼前节参数。连续变量数据采用独立样本t检验或Wilcoxon两样本检验比较两组差异,分类变量数据采用χ(2)检验。采用多元线性回归模型分析前房角的相关因素。中国汉族组和美国白种人组分别纳入118名受试者(118只眼)和117名受试者(117只眼)。与白种人相比,中国人A超测量的前房深度较小[(3.03±0.34)mm 比(3.38±0.36)mm,-5.791,P=0.001],相对晶状体位置较小[0.227(0.198,0.256)比0.235(0.191,0.262),-3.063,P=0.002],眼轴长度较小[23.3(20.9,28.3)mm比24.2(20.8,28.5)mm,-5.510,P=0.001],虹膜根部距离较小[0.111(0.000,0.401)mm比0.142(0.000,0.451)mm,-3.188,P=0.001],巩膜突后1mm处睫状体厚度较小[0.661(0.424,0.892)mm比0.716(0.467,0.942)mm,-3.456,P=0.001],小梁睫状突距离较小[0.780(0.410,1.400)mm比0.9…

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验