Suppr超能文献

Efficient Design of Real Time Bio-Signal Preprocessing for Wearable Devices.

作者信息

Yoon Seung Keun, Lee Jong Wook, Kwon Ui Kun, Ko Byung Hoon, Kim Youn Ho

出版信息

Annu Int Conf IEEE Eng Med Biol Soc. 2018 Jul;2018:1181-1184. doi: 10.1109/EMBC.2018.8512367.

Abstract

Wearable devices for body-status monitoring require various signal processing such as ambient noise filtering and signal quality evaluation. While wearable devices are very limited in resource, conventional noise filtering and signal quality evaluating methods consume considerable amount of processing power. Moreover, these conventional methods are not suitable for processing bio-signals in terms of its performance. In this paper, we propose a novel method of preprocessing bio-signals. This preprocessing method includes distortionless noise filtering and signal quality estimation, where both parts are basically based on a simple combination of multiple low pass IIR filters.