Chen T S, Han X, Liu Q, Li S S, Wen C, Wang W, Xu K X, Lin P
Department of Otorhinolaryngology Head and Neck Surgery, Tianjin First Center Hospital, Otorhinolaryngology Institute of Tianjin, Tianjin 300192, China.
Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2018 Nov 7;53(11):811-814. doi: 10.3760/cma.j.issn.1673-0860.2018.11.003.
To evaluate the data of unilateral centrifugation subjective visual vertical (UC-SVV) in healthy young people.To study the function of utricle. Between Decem ber 2017 and May 2018, thirty-two healthy young volunteers were tested by static subjective visual vertical(SVV) and low velocity UC-SVV with Neuro Kinetics Inc I-portal 6.0 Video nystagmus recording system and NOTC rotating chair system.The static SVV preset angle were -15.00°, 15.00°, -20.00°, 20.00°, -12.00° and 12.00° respectively.UC-SVV test parameters: rotating chair's peak speed was 60°/s.The shift time from the middle to the lateral position was 30 s and the displacement was 3.85 cm.The chair rotated at 60 s at left, right and middle positions.Subjects underwent SVV during this period.SPSS 17.0 software was used to analyze the data. The mean and standard deviation of static SVV deviation in 32 volunteers was 0.21°±0.17°, 95% (-0.14°, 0.55°). The mean and standard deviation of UC-SVV in the left, middle and right positions of the clockwise was 0.24°±0.25°, -0.10°±0.27°, -0.63°±0.26°, 95%(-0.26°, 0.74°), (-0.65°, 0.44°), (-1.16°, -0.10°). The mean and standard deviation of UC-SVV in the left, middle and right positions of the counter clockwise was 0.03°±0.27°, -0.11°±0.26°, -0.23°±0.26°, 95%(-0.52°, 0.59°), (-0.65°, 0.42°), (-0.76°, 0.30°). There was significant difference in the deviation between the left and the right side of counter clockwise rotation of UC-SVV(=2.432, <0.05), however, there was no significant difference in the angle of deviation between the left and right sides and the median position( value was 0.951, -1.400, both >0.05). There was no significant difference among each position in clockwise rotation of UC-SVV(=0.253, >0.05). UC-SVV test with peak speed of 60°/s can cause vertical line deviation in the left and right lateral position, but the angle is small and the value of clinical application is limited.
评估健康年轻人单侧离心主观视觉垂直(UC-SVV)的数据。研究椭圆囊的功能。2017年12月至2018年5月期间,32名健康年轻志愿者使用Neuro Kinetics Inc I-portal 6.0视频眼震记录系统和NOTC转椅系统进行了静态主观视觉垂直(SVV)和低速UC-SVV测试。静态SVV预设角度分别为-15.00°、15.00°、-20.00°、20.00°、-12.00°和12.00°。UC-SVV测试参数:转椅峰值速度为60°/秒。从中位到侧位的移位时间为30秒,位移为3.85厘米。转椅在左、右和中位各旋转60秒。在此期间受试者进行SVV测试。使用SPSS 17.0软件分析数据。32名志愿者静态SVV偏差的均值和标准差为0.21°±0.17°,95%可信区间为(-0.14°,0.55°)。顺时针方向UC-SVV在左、中、右位置的均值和标准差分别为0.24°±0.25°、-0.10°±0.27°、-0.63°±0.26°,95%可信区间为(-0.26°,0.74°)、(-0.65°,0.44°)、(-1.16°,-0.10°)。逆时针方向UC-SVV在左、中、右位置的均值和标准差分别为0.03°±0.27°、-0.11°±0.26°、-0.23°±0.26°,95%可信区间为(-0.52°,0.59°)、(-0.65°,0.42°)、(-0.76°,0.30°)。UC-SVV逆时针旋转时左侧与右侧的偏差有显著差异(=2.432,<0.05),然而,左侧与右侧以及中位之间的偏差角度无显著差异(值分别为0.951、-1.400,均>0.05)。UC-SVV顺时针旋转时各位置之间无显著差异(=0.253,>0.05)。峰值速度为60°/秒的UC-SVV测试可导致左右侧位出现垂直线偏差,但角度较小,临床应用价值有限。