Differences in signal intensities of temporomandibular joint (TMJ) effusion on fluid-attenuated inversion recovery (FLAIR) images.

作者信息

Otonari-Yamamoto Mika, Imoto Kenichi

机构信息

Department of Oral and Maxillofacial Radiology, Tokyo Dental College, 2-9-18, Misaki-cho, Chiyoda-ku, Tokyo, 101-0016, Japan.

出版信息

Oral Radiol. 2018 Sep;34(3):245-250. doi: 10.1007/s11282-018-0317-0. Epub 2018 Jan 20.

Abstract

OBJECTIVES

Joint effusion is demonstrated by high signal intensity in the upper and lower temporomandibular joint (TMJ) spaces on T2-weighted images. The fluid-attenuated inversion recovery (FLAIR) technique can be applied to analyze joint effusion in the TMJ. FLAIR signal intensity can be more sensitively influenced by the contents of joint effusion than T2-weighted signal intensity. The purpose of this study was to analyze the signal intensity of joint effusion on FLAIR images and to investigate the changes in joint effusion contents according to the status of TMJ disorders.

METHODS

A total of 48 joints (45 patients) with joint effusion were investigated by magnetic resonance (MR) imaging. Regions of interest were placed over the joint effusion and gray matter on FLAIR images. The joints were categorized as normal disk position (NL), disk displacement with reduction (DWR), disk displacement without reduction (DWOR), and osteoarthritis (OA). The signal intensity ratio of joint effusion was calculated using gray matter as the reference point. The Kruskal-Wallis test and Steel test were applied. A probability of less than 0.05 was considered statistically significant.

RESULTS

The median signal intensity ratios of joint effusion differed significantly among the four joint categories (p = 0.02, Kruskal-Wallis test). The median signal intensity ratio of joint effusion in the OA category was significantly higher than that in the NL category (p = 0.04, Steel test).

CONCLUSIONS

The present findings suggest that FLAIR images can demonstrate the changes in joint effusion contents according to the status of TMJ disorders.

摘要

目的

颞下颌关节(TMJ)上下间隙在T2加权图像上表现为高信号强度,提示有关节积液。液体衰减反转恢复(FLAIR)技术可用于分析颞下颌关节的关节积液。与T2加权信号强度相比,FLAIR信号强度受关节积液内容物的影响更敏感。本研究的目的是分析FLAIR图像上关节积液的信号强度,并根据颞下颌关节紊乱的状态研究关节积液内容物的变化。

方法

对48个有关节积液的关节(45例患者)进行磁共振(MR)成像检查。在FLAIR图像上,将感兴趣区置于关节积液和灰质上。这些关节被分类为正常盘位置(NL)、可复性盘移位(DWR)、不可复性盘移位(DWOR)和骨关节炎(OA)。以灰质为参考点,计算关节积液的信号强度比。应用Kruskal-Wallis检验和Steel检验。概率小于0.05被认为具有统计学意义。

结果

四个关节类别中关节积液的信号强度中位数差异有统计学意义(p = 0.02,Kruskal-Wallis检验)。OA类别中关节积液的信号强度中位数显著高于NL类别(p = 0.04,Steel检验)。

结论

本研究结果表明,FLAIR图像可以显示根据颞下颌关节紊乱状态而出现的关节积液内容物的变化。