金属对金属与金属对聚乙烯轴承初次全髋关节置换术的中期比较随访研究

Comparative Mid-term Follow-up Study of Primary Total Hip Arthroplasty with Metal-on-metal and Metal-on-polyethylene Bearings.

作者信息

Li Zhi, Chen Zhe-Feng, Liu Jiu-Xiang, Liu Feng

机构信息

Department of Orthopaedic Surgery, Geriatric Hospital, Nanjing Medical University, Nanjing, China.

Department of Orthopaedic Surgery, The First Affiliated Hospital, Nanjing Medical University, Nanjing, China.

出版信息

Orthop Surg. 2018 Nov;10(4):312-320. doi: 10.1111/os.12408.

Abstract

OBJECTIVE

To compare mid-term clinical results of total hip arthroplasty (THA) with metal-on-metal (MoM) and metal-on-polyethylene (MoP) bearings and to evaluate the biological safety of the two kinds of prostheses.

METHODS

Thirty-two patients who received a primary THA with an MoM articulation between January 2008 and December 2010 were selected to form the MoM group retrospectively. The MoP group consisted of 32 patients who received a THA with an MoP prosthesis during the same period. Clinical assessments, imaging examinations, laboratory tests, and metal ion concentration detections were conducted on each patient. Another 32 healthy volunteers were recruited as the control group.

RESULTS

Twenty-seven patients in the MoM group and 28 patients in the MoP group completed the follow-up, with a mean follow-up time of 74.6 and 75.9 months, respectively. The mean Harris score at the latest follow-up was 91.5 ± 5.1 in the MoM group versus 88.9 ± 4.0 in the MoP group (P = 0.22). The MoM group showed a better range of motion in flexion, abduction, and external rotation. Co and Cr levels in the MoM group were 2.5-fold and 2.0-fold of these in the MoP group. A mild change of liver function was observed in both groups, while the values of renal function and humoral immunity stayed static. Elevated proportions of Th1 and Th17 cells and decreased proportion of Th2 cells were observed in the MoM group. The occurrence rate of pseudotumors in the MoM and MoP groups was 40.74% ± 9.45% and 14.28% ± 6.61%, respectively (P < 0.05).

CONCLUSION

At the mid-term follow-up, clinical results were satisfied in both groups. MoM prosthesis could result in elevated serum metal ion levels and there is a higher risk of pseudotumor. Long follow-up is needed to evaluate the safety of MoM prostheses.

摘要

目的

比较金属对金属(MoM)和金属对聚乙烯(MoP)轴承全髋关节置换术(THA)的中期临床结果,并评估两种假体的生物安全性。

方法

回顾性选取2008年1月至2010年12月期间接受初次MoM关节置换THA的32例患者组成MoM组。MoP组由同期接受MoP假体THA的32例患者组成。对每位患者进行临床评估、影像学检查、实验室检查和金属离子浓度检测。另招募32名健康志愿者作为对照组。

结果

MoM组27例患者、MoP组28例患者完成随访,平均随访时间分别为74.6个月和75.9个月。MoM组末次随访时Harris评分均值为91.5±5.1,MoP组为88.9±4.0(P = 0.22)。MoM组在屈曲、外展和外旋活动度方面表现更佳。MoM组钴和铬水平分别是MoP组的2.5倍和2.0倍。两组均观察到肝功能轻度变化,而肾功能和体液免疫值保持稳定。MoM组Th1和Th17细胞比例升高,Th2细胞比例降低。MoM组和MoP组假瘤发生率分别为40.74%±9.45%和14.28%±6.61%(P < 0.05)。

结论

中期随访时两组临床结果均令人满意。MoM假体可导致血清金属离子水平升高,假瘤风险更高。需要长期随访以评估MoM假体的安全性。