用于表面近距离放射治疗的国产镥贴片源剂量测定——实验方法与蒙特卡罗方法

Dosimetry of indigenously developed Lu patch source for surface brachytherapy-Experimental and Monte Carlo methods.

作者信息

Sahoo Sridhar, Shrivastava Vandana, Selvam T Palani, Bakshi A K, Kumar Rajesh, Rama P, Datta D, Chinnaesakki S, Saxena S K, Kumar Yogendra, Dash A

机构信息

Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai-400 085, India. Homi Bhabha National Institute, Mumbai-400 094, India.

出版信息

J Radiol Prot. 2019 Jan;39(1):54-70. doi: 10.1088/1361-6498/aaeeb6. Epub 2018 Nov 6.

Abstract

This paper describes the evaluation of dosimetry characteristics of an in-house developed Lu skin patch source for treatment of non-melanoma skin cancer. A Lu skin patch source based on Nafion-115 membrane backbone containing 3.46 ± 0.01 mCi of activity was used. Activity measurement of the patch source was based on gamma ray spectrometry using a HPGe detector. The efficiencies of the HPGe detector were fitted using an orthogonal polynomial function. The absorbed dose rate to water at 5 μm depth in water was determined using an extrapolation chamber, EBT3 Gafchromic film and compared with Monte Carlo methods. The correction factors such as Bragg-Gray stopping power ratio of water-to-air and chamber wall material being different from water, needed to be applied on measurements for establishing the dose rate at 5 μm depth, were calculated using the Monte Carlo method. Absorbed dose rate at 5 μm depth in water (surface dose rate) measured using an extrapolation chamber and EBT3 Gafchromic film were 9.9 ± 0.7 and 8.2 ± 0.1 Gy h mCi respectively for the source activity of 3.46 ± 0.01 mCi. The surface dose rate calculated using the Monte Carlo method was 8.7 ± 0.2 Gy h mCi, which agrees reasonably well with measurement. The measured dose rate per mCi offers scope for ascertaining treatment time required to deliver the dose for propitious therapeutic outcome. Additionally, on-axis depth dose and lateral dose profiles at 5 μm and 1 mm depth in water phantom were also calculated using the Monte Carlo method.

摘要

本文描述了对一种自行研制的用于治疗非黑色素瘤皮肤癌的镥皮肤贴片源的剂量学特性评估。使用了一种基于Nafion - 115膜骨架、活度为3.46±0.01 mCi的镥皮肤贴片源。贴片源的活度测量基于使用HPGe探测器的γ射线能谱法。HPGe探测器的效率用正交多项式函数拟合。使用外推电离室、EBT3变色薄膜确定水中5μm深度处水的吸收剂量率,并与蒙特卡罗方法进行比较。对于在5μm深度处确定剂量率的测量,需要应用诸如水与空气的布拉格 - 格雷阻止本领比以及电离室壁材料与水不同等校正因子,这些校正因子使用蒙特卡罗方法计算。对于活度为3.46±0.01 mCi的源,使用外推电离室和EBT3变色薄膜测量的水中5μm深度处(表面剂量率)的吸收剂量率分别为9.9±0.7和8.2±0.1 Gy h mCi。使用蒙特卡罗方法计算的表面剂量率为8.7±0.2 Gy h mCi,与测量结果相当吻合。每毫居里测量的剂量率为确定为获得良好治疗效果而输送剂量所需的治疗时间提供了空间。此外,还使用蒙特卡罗方法计算了水模体中5μm和1mm深度处的轴上深度剂量和侧向剂量分布。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验