The complement-dependent cytotoxicity typing assay was studied for its accuracy in determining the presence of donor lymphocytes within standard chimeric donor/host cell combinations. Regression analysis of the data was utilized to evaluate the chimera assay. Excellent coefficients of determination (r2 greater than 0.90) were obtained for all standard curves, and a significant (P less than 0.001) linear relationship was established between percent cytotoxicity (dependent variable) and level of donor target cell chimerism (independent variable) for each regression equation. A highly significant (P less than 0.001) linear function was also established between percent cytotoxicity and concentration of donor target bone marrow cells. Regression coefficients (slopes) approached, but did not show complete unity (range; b = 0.86-0.95). Therefore, levels of cytotoxicity were not directly equivalent to levels of donor cell chimerism. A more accurate assessment of donor lymphoid chimerism would be provided by regression analysis of standard donor/host cell independent variables and inverse prediction. Significant estimates of peripheral donor lymphoid chimerism in putative mixed chimeric recipients were successfully made by this technique.
研究了补体依赖性细胞毒性分型测定法在确定标准嵌合供体/宿主细胞组合中供体淋巴细胞存在情况时的准确性。利用数据的回归分析来评估嵌合体测定法。所有标准曲线的决定系数均极佳(r2大于0.90),并且每个回归方程的细胞毒性百分比(因变量)与供体靶细胞嵌合水平(自变量)之间建立了显著(P小于0.001)的线性关系。细胞毒性百分比与供体靶骨髓细胞浓度之间也建立了高度显著(P小于0.001)的线性函数关系。回归系数(斜率)接近但未显示完全一致(范围;b = 0.86 - 0.95)。因此,细胞毒性水平与供体细胞嵌合水平并不直接等同。通过对标准供体/宿主细胞自变量进行回归分析和反向预测,可以更准确地评估供体淋巴嵌合情况。通过该技术成功地对假定的混合嵌合受体中的外周供体淋巴嵌合情况进行了显著估计。