Suppr超能文献

超声引导下仅皮质视图肾脏移植活检的诊断效能和安全性:一项回顾性单中心研究。

Diagnostic efficacy and safety of ultrasound-guided kidney transplant biopsy using cortex-only view: a retrospective single-center study.

机构信息

Department of Radiology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-752, Republic of Korea.

Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.

出版信息

Eur Radiol. 2019 Oct;29(10):5272-5279. doi: 10.1007/s00330-018-5910-4. Epub 2018 Dec 17.

Abstract

PURPOSE

Cortical biopsy is the cornerstone to reveal a cause of unexplained dysfunction of the kidney transplant. Nevertheless, only a few studies have reported the biopsy technique with its performance. We described a novel technique of ultrasound (US)-guided kidney transplant biopsy using cortex-only view and analyzed its diagnostic efficacy and safety.

MATERIALS AND METHODS

Between January 2014 and December 2016, a consecutive series of 188 patients who underwent US-guided kidney transplant biopsy using cortex-only view by an experienced radiologist were evaluated (mean age, 46.1 ± 12.5 years; range, 21-79 years). Biopsy time, biopsy distance, biopsy core number, and glomerular number per patient were recorded. Successful biopsy (e.g., adequate, 10 or more glomeruli; marginal, 7-9 glomeruli) and complication rates were investigated, using Banff criteria and Clavien-Dindo classification, respectively.

RESULTS

Mean biopsy time, distance, and core number were 20.6 ± 6.7 min (range, 10-44 min), 3.2 ± 0.7 cm (range, 2.1-5.4 cm), and 1.9 ± 0.3 (range, 1.0-3.0), respectively. Mean glomerular number per patient was 20.4 ± 10.0 (range, 0-54). Adequate and marginal biopsy rates were 87.2% (164/188) and 95.2% (179/188), respectively. There was no major complication requiring treatment (no patient with Clavien-Dindo grade 2 or greater complication), while there were self-limiting minor complications in 5 patients (overall complication rate, 2.7%).

CONCLUSION

US-guided biopsy using cortex-only view is feasible and safe in sampling cortical tissues of kidney transplant.

KEY POINTS

• Ultrasound (US)-guided kidney transplant biopsy using cortex-only view is feasible and safe. • Adequate and marginal biopsy rates were 87.2% and 95.2%, respectively. • No major complication requiring treatment occurred after biopsy.

摘要

目的

皮质活检是揭示不明原因肾功能障碍的肾移植病因的基石。然而,只有少数研究报道了活检技术及其性能。我们描述了一种新的超声(US)引导肾移植活检技术,使用皮质仅视图,并分析其诊断效果和安全性。

材料和方法

2014 年 1 月至 2016 年 12 月,连续评估了 188 例接受 US 引导的皮质仅视图肾移植活检的患者(平均年龄 46.1±12.5 岁;范围 21-79 岁)。记录活检时间、活检距离、活检核心数和每位患者的肾小球数。使用 Banff 标准和 Clavien-Dindo 分类分别研究了成功活检(例如,充足,10 个或更多肾小球;边缘,7-9 个肾小球)和并发症的发生率。

结果

平均活检时间、距离和核心数分别为 20.6±6.7 分钟(范围 10-44 分钟)、3.2±0.7 厘米(范围 2.1-5.4 厘米)和 1.9±0.3(范围 1.0-3.0),每位患者的平均肾小球数为 20.4±10.0(范围 0-54)。充足和边缘活检率分别为 87.2%(164/188)和 95.2%(179/188)。没有需要治疗的主要并发症(没有 Clavien-Dindo 2 级或更高级别并发症的患者),而 5 例患者出现自限性轻微并发症(总并发症率为 2.7%)。

结论

超声引导的仅使用皮质视图的活检在取样肾移植的皮质组织方面是可行和安全的。

重点

• 使用皮质仅视图的超声(US)引导的肾移植活检是可行和安全的。• 充足和边缘活检率分别为 87.2%和 95.2%。• 活检后未发生需要治疗的主要并发症。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验